EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters

Zhaoyu Qin, Yan Zhang, Yuli Wang, Ge Wang, Xiaoyi Cheng

Applied Sciences · 24.04.2026 · 16 (9) · 4202

DOI: 10.3390/app16094202 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 24.04.2026. Verfasst von Zhaoyu Qin und 4 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Electric Power Research Institute.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing integration of nonlinear loads in modern power systems has made harmonic pollution a critical challenge to the operational safety of power cables. This study develops a frequency-dependent high-voltage cable system model using the ATP-EMTP (Alternative Transients Program-Electro Magnetic Transient Program) electromagnetic transient simulation platform, systematically investigating the amplification mechanisms and propagation characteristics of grounding currents under multi-type harmonic disturbances. A frequency-dependent parameter correction model is established by integrating the conductor skin effect and the dielectric relaxation properties of the insulation layers. This model incorporates the multi-structure combination among conductors, insulation, and metallic screen. It effectively overcomes the limitations of conventional lumped-parameter models in higher frequency harmonic analysis. Key findings are as follows: (1) The combined influence of harmonic frequency and amplitude leads to a grounding current amplification of up to 445 times (at 1950 Hz with 30% distortion level). Notably, current-source excitation produces significantly greater amplification than voltage-source excitation. (2) The distributed capacitance of long-distance cables (>8 km) exacerbates resonance risks within specific frequency bands (750–1250 Hz), resulting in a maximum harmonic amplification factor of 34.73 (observed for the 17th harmonic in a 15 km cable). (3) The contribution of voltage-source harmonics diminishes to less than 5% of the total current at high frequencies (≥1250 Hz), indicating a pattern of current-dominated harmonic superposition.

Förderung

  • China Electric Power Research Institute

Zitieren

APA

Qin, Z., Zhang, Y., Wang, Y., Wang, G., & Cheng, X. (2026). Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters. Applied Sciences, 16(9), 4202. https://doi.org/10.3390/app16094202

Vancouver

Qin Z, Zhang Y, Wang Y, Wang G, Cheng X. Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters. Applied Sciences. 2026;16(9):4202. doi:10.3390/app16094202

BibTeX
@article{Qin2026,
  author = {Qin, Zhaoyu and Zhang, Yan and Wang, Yuli and Wang, Ge and Cheng, Xiaoyi},
  title = {Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {4202},
  doi = {10.3390/app16094202}
}
Kostenlos starten →