EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Absolute and Individualized Physical Activity Intensity Thresholds Using Non-Dominant Wrist-Worn Accelerometry in Military Office Workers

Maaike Polspoel, Tara Reilly, Damien Van Tiggelen, Patrick Calders

Applied Sciences · 17.04.2026 · 16 (8) · 3931

DOI: 10.3390/app16083931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.04.2026. Verfasst von Maaike Polspoel und 3 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Higher Institute for Defense.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate classification of physical activity (PA) intensity is essential for exercise prescription, rehabilitation monitoring, and evaluation of guideline adherence. However, widely used wrist-worn accelerometer cut-points may substantially misclassify physiological intensity. This study evaluated absolute accelerometer thresholds during a maximal 2400 m run in military office workers and examined whether individualized cut-points improve agreement with physiological intensity. Seventy-four military office workers completed the test while wearing a wrist-worn ActiGraph GT9X Link and a chest-worn Zephyr BioHarness. Participants achieved near-maximal physiological effort, with peak heart rate averaging 187 ± 11 bpm (95 ± 4.2% age-predicted HRmax). Despite this high intensity, absolute wrist-worn cut-points classified only 34.5% of participants as performing vigorous activity for most of the test. Individualized cut-points, derived from each participant’s individual reference intensity, calculated as the three highest consecutive one-minute epochs during the 2400 m test, substantially improved agreement between accelerometer-derived classifications and physiological intensity. Agreement with %HRmax increased from fair (κ = 0.31), using absolute thresholds, to good (κ = 0.74), using individualized thresholds, and intraclass correlation increased from 0.52 to 0.81. These findings demonstrate that absolute cut-points markedly underestimate high-intensity activity, potentially leading to inaccurate exercise load monitoring and misinterpretation of training intensity. Individualized calibration during a standardized maximal running test provides a feasible strategy to improve the validity of intensity assessment using wearables. Although the study population consisted of military office workers, the approach may be applicable to other active populations. However, further validation in independent samples is needed.

Förderung

  • Royal Higher Institute for Defense

Zitieren

APA

Polspoel, M., Reilly, T., Tiggelen, D. V., & Calders, P. (2026). Comparison of Absolute and Individualized Physical Activity Intensity Thresholds Using Non-Dominant Wrist-Worn Accelerometry in Military Office Workers. Applied Sciences, 16(8), 3931. https://doi.org/10.3390/app16083931

Vancouver

Polspoel M, Reilly T, Tiggelen DV, Calders P. Comparison of Absolute and Individualized Physical Activity Intensity Thresholds Using Non-Dominant Wrist-Worn Accelerometry in Military Office Workers. Applied Sciences. 2026;16(8):3931. doi:10.3390/app16083931

BibTeX
@article{Polspoel2026,
  author = {Polspoel, Maaike and Reilly, Tara and Tiggelen, Damien Van and Calders, Patrick},
  title = {Comparison of Absolute and Individualized Physical Activity Intensity Thresholds Using Non-Dominant Wrist-Worn Accelerometry in Military Office Workers},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {8},
  pages = {3931},
  doi = {10.3390/app16083931}
}
Kostenlos starten →