EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy

Umberto Crimaldi, Nastassja Luongo, Laura Antonia Cerbone, Roberto Pacelli, Paolo Russo, Giovanni Mettivier

Applied Sciences · 28.03.2026 · 16 (7) · 3282

DOI: 10.3390/app16073282 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 28.03.2026. Verfasst von Umberto Crimaldi und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PNRR project, INFN.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Spatially fractionated radiotherapy with X-ray minibeams (x-MBRT) aims to increase normal-tissue tolerance by delivering alternating high- and low-dose regions. We provide a Monte Carlo-based framework to design and optimize multi-slit collimators, quantifying how geometry and material govern peak–valley modulation. A validated digital twin of the SmART X-RAD225Cx irradiator was implemented in TOPAS/Geant4. Various x-MBRT collimators were simulated with parallel or divergent slits. The parameter space covered a slit width w (0.1–0.9 mm), center-to-center spacing CTC (1–3 mm), thickness T (1–5 mm), and acceptance angle θ. Dose was scored in a 2 × 2 × 2 cm3 water phantom at a 1 cm depth. For fixed w/CTC, peak-valley dose ratio PVDR increases with larger CTC via an increase in peak dose, with the valley dose nearly constant. Peak transmission saturated at θ ≈ 3°, indicating minimal benefit from larger acceptance. Divergent slits yielded flatter lateral profiles but higher valley doses than parallel slits, reducing PVDR around the central axis. This Monte Carlo study provides insights for optimizing collimator geometries in x-MBRT using small-animal irradiators, informing the design of more effective collimation systems to enhance treatment precision and normal-tissue sparing.

Förderung

  • PNRR project
  • INFN

Zitieren

APA

Crimaldi, U., Luongo, N., Cerbone, L. A., Pacelli, R., Russo, P., & Mettivier, G. (2026). Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy. Applied Sciences, 16(7), 3282. https://doi.org/10.3390/app16073282

Vancouver

Crimaldi U, Luongo N, Cerbone LA, Pacelli R, Russo P, Mettivier G. Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy. Applied Sciences. 2026;16(7):3282. doi:10.3390/app16073282

BibTeX
@article{Crimaldi2026,
  author = {Crimaldi, Umberto and Luongo, Nastassja and Cerbone, Laura Antonia and Pacelli, Roberto and Russo, Paolo and Mettivier, Giovanni},
  title = {Design and Optimization of X-Ray Collimators for Preclinical Minibeam Radiation Therapy},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {3282},
  doi = {10.3390/app16073282}
}
Kostenlos starten →