EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of 45° and 90° Medial Row Anchor Insertion Angles in Double-Row Suture Bridge Rotator Cuff Repair: A Biomechanical and Finite Element Analysis

Ali İhsan Kılıç, Samet Çıklaçandır, Mustafa Çeltik, Sercan Çapkin, Ali Ersen, Onur Başçı

Applied Sciences · 23.03.2026 · 16 (6) · 3084

DOI: 10.3390/app16063084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 23.03.2026. Verfasst von Ali İhsan Kılıç und 5 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotator cuff suture anchors have traditionally been inserted at the 45° “deadman” angle, but this recommendation was largely derived from single-row constructs and may not reflect the biomechanics of contemporary double-row suture bridge repairs. This study compared the biomechanical performance and stress distribution of medial row anchors inserted at 45° versus 90° in a double-row suture bridge construct. Sixteen ovine humeri with intact infraspinatus tendons were randomized to 45° or 90° medial anchor insertion (n = 8 each), and double-row suture bridge repair was performed using 3.5 mm metallic and PEEK anchors. Specimens underwent uniaxial tensile testing (10-N preload, 5 mm/min) to failure, measuring yield load, failure load, displacement, stiffness, and energy absorption; additionally, a CT-based finite element model of the human humerus assessed von Mises stress, strain, and deformation under 200 N loading. Mean failure load was 161.96 ± 50.99 N for 45° and 185.61 ± 60.97 N for 90° (p = 0.447), and stiffness was 31.63 ± 8.18 N/mm versus 36.79 ± 9.26 N/mm (p = 0.291). Displacement at failure was greater with 90° insertion (8.11 ± 0.51 mm vs. 6.65 ± 0.83 mm; p = 0.002), while energy absorption was higher but not significantly different (p = 0.255). Finite element analysis demonstrated lower bone von Mises stress with 90° insertion (14.03 MPa) compared with 45° (24.77 MPa), with similar deformation. In double-row suture bridge repair, 90° medial anchor insertion provides comparable fixation strength to that at 45° while reducing bone stress, suggesting a biomechanical advantage.

Zitieren

APA

Kılıç, A. İ., Çıklaçandır, S., Çeltik, M., Çapkin, S., Ersen, A., & Başçı, O. (2026). Comparison of 45° and 90° Medial Row Anchor Insertion Angles in Double-Row Suture Bridge Rotator Cuff Repair: A Biomechanical and Finite Element Analysis. Applied Sciences, 16(6), 3084. https://doi.org/10.3390/app16063084

Vancouver

Kılıç Aİ, Çıklaçandır S, Çeltik M, Çapkin S, Ersen A, Başçı O. Comparison of 45° and 90° Medial Row Anchor Insertion Angles in Double-Row Suture Bridge Rotator Cuff Repair: A Biomechanical and Finite Element Analysis. Applied Sciences. 2026;16(6):3084. doi:10.3390/app16063084

BibTeX
@article{Kl2026,
  author = {Kılıç, Ali İhsan and Çıklaçandır, Samet and Çeltik, Mustafa and Çapkin, Sercan and Ersen, Ali and Başçı, Onur},
  title = {Comparison of 45° and 90° Medial Row Anchor Insertion Angles in Double-Row Suture Bridge Rotator Cuff Repair: A Biomechanical and Finite Element Analysis},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {3084},
  doi = {10.3390/app16063084}
}
Kostenlos starten →