EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Consequence-Based Assessment of Hydrogen Jet-Fire Hazards in a Port Hydrogen Refueling Station: Theory–CFD Coupling and Wind-Affected Thermal Impact Zoning

Liying Zhong, Ming Yang, Shuang Liu, Ting Liu, Weiyi Cui, Liang Tong

Applied Sciences · 16.03.2026 · 16 (6) · 2859

DOI: 10.3390/app16062859 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.03.2026. Verfasst von Liying Zhong und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technical Consultation Project for China Energy Engineering Group Guangxi Electric Power De-sign Institute Co., Ltd, Natural Science Foundation of Hubei Province of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Port-area hydrogen refueling stations face low-frequency but high-consequence events when high-pressure leaks ignite as jet fires in wind-exposed, constrained environments. This study develops a consequence-based framework coupling theoretical screening, CFD combustion analysis, and hazard zoning to support separation-distance setting and emergency planning. A jet-fire model estimates flame-impingement distances for multiple leak diameters, and a weighted multi-point radiation model predicts heat-flux fields, from which lethal and irreversible-injury zones are delineated using thresholds of 7 and 5 kW/m2, respectively. To move beyond wind-free screening, steady reacting-flow CFD is conducted for a representative release under four ambient conditions, with 4.34 m/s adopted as the representative wind speed for the windy cases based on Ningbo Port conditions. Validation against a visible-flame correlation defined by T ≥ 1573 K shows a deviation of 6.99%. Results show that radiation footprints expand markedly with diameter, with lethal and injury distances scaling approximately linearly within the studied range. Under wind, near-ground hot-plume extents defined by T ≥ 388 K and T ≥ 582 K depend strongly on wind direction and station geometry, whereas visible flame length is less sensitive. Additional sensitivity analyses indicate that the quasi-steady results are weakly affected by the selected ignition snapshot, while inclined releases modify projected plume/flame extents without altering the main engineering interpretation of the baseline case. The results support theory-based preliminary screening, but wind direction should be explicitly considered in exclusion-zone definition.

Förderung

  • Technical Consultation Project for China Energy Engineering Group Guangxi Electric Power De-sign Institute Co., Ltd
  • Natural Science Foundation of Hubei Province of China

Zitieren

APA

Zhong, L., Yang, M., Liu, S., Liu, T., Cui, W., & Tong, L. (2026). Consequence-Based Assessment of Hydrogen Jet-Fire Hazards in a Port Hydrogen Refueling Station: Theory–CFD Coupling and Wind-Affected Thermal Impact Zoning. Applied Sciences, 16(6), 2859. https://doi.org/10.3390/app16062859

Vancouver

Zhong L, Yang M, Liu S, Liu T, Cui W, Tong L. Consequence-Based Assessment of Hydrogen Jet-Fire Hazards in a Port Hydrogen Refueling Station: Theory–CFD Coupling and Wind-Affected Thermal Impact Zoning. Applied Sciences. 2026;16(6):2859. doi:10.3390/app16062859

BibTeX
@article{Zhong2026,
  author = {Zhong, Liying and Yang, Ming and Liu, Shuang and Liu, Ting and Cui, Weiyi and Tong, Liang},
  title = {Consequence-Based Assessment of Hydrogen Jet-Fire Hazards in a Port Hydrogen Refueling Station: Theory–CFD Coupling and Wind-Affected Thermal Impact Zoning},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {2859},
  doi = {10.3390/app16062859}
}
Kostenlos starten →