Design of the Post-Dispersion System for Coherent-Dispersion Spectrometer
Applied Sciences · 11.03.2026 · 16 (6) · 2658
DOI: 10.3390/app16062658 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 11.03.2026. Verfasst von Xiuxiu Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Research and Development Project of Hubei Province.
Abstract (Originalsprache)
Coherent-dispersion spectroscopy enables high-precision Doppler measurements of stellar spectral lines, which serves as a vital technique for the indirect detection of exoplanets. In this study, the post-dispersion system of a coherent-dispersion spectrometer (CODES) was designed and optimized using Zemax, with the detection spectral range of 656 nm–716 nm and a spectral resolution of 0.06 nm. The relay optical path adopted a combination of a cylindrical lens group and an image slicer, which reshaped the circular spot with a diameter of 630 μm into a linear spot of 27 μm × 2038.8 μm, effectively matching the slit size and improving the light throughput. A flat-field design was employed for the dispersion module, which adopted two structures: the Czerny–Turner spectrometer and the Dyson spectrometer. Both spectrometer structures were designed and optimized, and their aberrations and structural characteristics were comparatively analyzed. The on-axis Modulation Transfer Function (MTF) values at the central wavelength of the two spectrometers were 0.4@37 lp/mm and 0.8@37 lp/mm, respectively, and both the spectral resolution and imaging resolution could meet the design requirements. This work provides a feasible design idea for high-precision CODES for exoplanet detection as well as general medium-to-high resolution spectrometers.
Förderung
- National Natural Science Foundation of China
- Key Research and Development Project of Hubei Province
Zitieren
APA
Zhang, X., Wei, R., Xie, Z., Yin, R., Liu, X., & Liao, C. (2026). Design of the Post-Dispersion System for Coherent-Dispersion Spectrometer. Applied Sciences, 16(6), 2658. https://doi.org/10.3390/app16062658
Vancouver
Zhang X, Wei R, Xie Z, Yin R, Liu X, Liao C. Design of the Post-Dispersion System for Coherent-Dispersion Spectrometer. Applied Sciences. 2026;16(6):2658. doi:10.3390/app16062658
BibTeX
@article{Zhang2026,
author = {Zhang, Xiuxiu and Wei, Ruyi and Xie, Zhengmao and Yin, Rui and Liu, Xinghai and Liao, Chengsheng},
title = {Design of the Post-Dispersion System for Coherent-Dispersion Spectrometer},
journal = {Applied Sciences},
year = {2026},
volume = {16},
number = {6},
pages = {2658},
doi = {10.3390/app16062658}
}
EUVIMED