EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating

Jung-Eun Park, Yong-Seok Jang, Seung-O Ko, Min-Ho Lee

Applied Sciences · 03.02.2026 · 16 (3) · 1542

DOI: 10.3390/app16031542 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 03.02.2026. Verfasst von Jung-Eun Park und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Biomedical Research Institute, Jeonbuk National University Hospital, Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnesium has attracted attention as an orthopedic implant material due to its excellent biocompatibility and biodegradability; however, rapid corrosion in physiological environments remains a major limitation. In this study, a polydopamine (PDA) intermediate layer and alginate/chitosan multilayer coating were formed on pure magnesium surfaces, with dexamethasone incorporation to simultaneously improve corrosion resistance and bioactivity. SEM observation revealed that uniform coating layers were formed on alginate/chitosan multilayer coated specimens, and the chemical structure of the coating layers was confirmed through FT-IR and XRD analyses. Electrochemical analysis revealed that the PDA/alginate/chitosan coating group exhibited higher corrosion potential (Ecorr: −0.7514 ± 0.022 V vs. −1.706 ± 0.001 V) and lower corrosion current density (icorr: 2.275 ± 0.15 × 10−7 A/cm2 vs. 1.528 ± 0.47 × 10−4 A/cm2) compared to pure magnesium, with the highest impedance indicating superior corrosion resistance. In tape peel testing, the polydopamine-coated group demonstrated superior adhesion compared to the non-coated group, and sustained release of dexamethasone was confirmed. MC3T3-E1 cell culture results confirmed cell proliferation in all specimens, with the PDA/alginate/chitosan group exhibiting the highest ALP activity compared to other surface-treated groups. Based on these results, the PDA/alginate/chitosan multilayer coating was confirmed to be an effective surface modification method for corrosion control and promotion of osteoblast differentiation on magnesium.

Förderung

  • Biomedical Research Institute, Jeonbuk National University Hospital
  • Ministry of Education

Zitieren

APA

Park, J., Jang, Y., Ko, S., & Lee, M. (2026). Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating. Applied Sciences, 16(3), 1542. https://doi.org/10.3390/app16031542

Vancouver

Park J, Jang Y, Ko S, Lee M. Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating. Applied Sciences. 2026;16(3):1542. doi:10.3390/app16031542

BibTeX
@article{Park2026,
  author = {Park, Jung-Eun and Jang, Yong-Seok and Ko, Seung-O and Lee, Min-Ho},
  title = {Functional Surface Modification of Magnesium Implant by Drug-Loaded Biodegradable Polymer Coating},
  journal = {Applied Sciences},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {1542},
  doi = {10.3390/app16031542}
}
Kostenlos starten →