Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 06.12.2025. Verfasst von Cristina Nuevo-Gallardo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agencia Estatal de Investigación.
Abstract (Originalsprache)
The transition toward energy-efficient and smart buildings requires Digital Twins (DTs) that can couple real-time data with physics-based Building Energy Models (BEMs) for predictive and adaptive operation. Yet, despite rapid digitalisation, there remains a lack of practical guidance and real-world implementations demonstrating how calibrated BEMs can be effectively integrated into Building Management Systems (BMSs). This study addresses that gap by presenting a complete and reproducible end-to-end framework for embedding physics-based BEMs into operational DTs using two setups: (i) encapsulation as Functional Mock-up Units (FMUs) and (ii) containerisation via Docker. Both approaches were deployed and tested in a real educational building in Cáceres (Spain), equipped with a LoRaWAN-based sensing and actuation infrastructure. A systematic comparison highlights their respective trade-offs: FMUs offer faster execution but limited weather inputs and higher implementation effort, whereas Docker-based workflows provide full portability, scalability, and native interoperability with Internet of Things (IoT) and BMS architectures. To enable real-time operation, a surrogate modelling framework was embedded within the Docker architecture to replicate the optimisation logic of the calibrated BEM and generate predictive blind control schedules in milliseconds—bypassing simulation overhead and enabling continuous actuation. The combined Docker + surrogate setup achieved 10–15% heating energy savings during winter operation without any HVAC retrofit. Beyond the case study, this work provides a step-by-step, in-depth guideline for practitioners to integrate calibrated BEMs into real-time control loops using existing toolchains. The proposed approach demonstrates how hybrid physics- and data-driven DTs can transform building management into a scalable, energy-efficient, and operationally deployable reality.
Förderung
- Agencia Estatal de Investigación
Zitieren
APA
Nuevo-Gallardo, C., Barrio, I. L. D., Iglesias, M. F., Trueba, J. B. E., & Bandera, C. F. (2025). Real-Time Digital Twins for Building Energy Optimization Through Blind Control: Functional Mock-Up Units, Docker Container-Based Simulation, and Surrogate Models. Applied Sciences, 15(24), 12888. https://doi.org/10.3390/app152412888
Vancouver
Nuevo-Gallardo C, Barrio ILD, Iglesias MF, Trueba JBE, Bandera CF. Real-Time Digital Twins for Building Energy Optimization Through Blind Control: Functional Mock-Up Units, Docker Container-Based Simulation, and Surrogate Models. Applied Sciences. 2025;15(24):12888. doi:10.3390/app152412888
BibTeX
@article{NuevoGallardo2025,
author = {Nuevo-Gallardo, Cristina and Barrio, Iker Landa del and Iglesias, Markel Flores and Trueba, Juan B. Echeverría and Bandera, Carlos Fernández},
title = {Real-Time Digital Twins for Building Energy Optimization Through Blind Control: Functional Mock-Up Units, Docker Container-Based Simulation, and Surrogate Models},
journal = {Applied Sciences},
year = {2025},
volume = {15},
number = {24},
pages = {12888},
doi = {10.3390/app152412888}
}
EUVIMED