EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Type-3 Fuzzy Logic-Based Robust Speed Control for an Indirect Vector-Controlled Induction Motor

Cafer Bal

Applied Sciences · 12.11.2025 · 15 (22) · 11994

DOI: 10.3390/app152211994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 12.11.2025. Verfasst von Cafer Bal. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Firat University Scientific Research Projects Coordination Unit.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Induction motors require effective speed controllers to handle challenging conditions such as indirect vector control, nonlinear dynamics, load-disturbances, and changes in rotor resistance. Although proportional–integral (PI) controllers and type-1 fuzzy logic controllers (T1-FLC) are relatively straightforward to implement, they can produce significant overshoot and slow recovery; type-2 fuzzy logic controllers (T2-FLC), on the other hand, improve uncertainty management at the cost of higher computational complexity. This study proposes a type-3 fuzzy logic controller (T3-FLC) that balances robustness with a single α-slice using two inputs and seven membership functions per input (49 rules). In six comparison scenarios, the type-3 FLC (T3-FLC) consistently offers a lower overshoot percentage and shorter recovery/settling times than the PI controller and type-1 FLC (T1-FLC). Overshoot drops to 0.13% with T3-FLC during a high-speed positive step, while this value for the PI controller is 4.43%. During a low-amplitude positive step, T3-FLC reaches 1.37%, while the PI controller reaches 11.12% and T1-FLC reaches 4.13%. After load torque is removed, the recovery time trec under T3-FLC is 0.064 s at high speed and 0.158 s at low speed, while for PI, these values are 0.400 s and 1.975 s, respectively. Under variations in rotor resistance, T3-FLC maintains a significantly smaller overshoot value: with a −20% change (3–6 s window), the values are 1.45% (T3-FLC) versus 9.59% (PI) and 4.51% (T1-FLC); with a +20% change (3–6 s), the values are 0.14% (T3-FLC) versus 4.36% (PI) and 0.15% (T1-FLC). Although there are isolated cases in which PI or T1-FLC shows a marginal advantage in a single metric (e.g., slightly smaller overshoot during transition or lower peak error during disturbance), T3-FLC generally provides the best balance, combining low overshoot with short settling/recovery time while keeping steady-state error at zero in all scenarios.

Förderung

  • Firat University Scientific Research Projects Coordination Unit

Zitieren

APA

Bal, C. (2025). Type-3 Fuzzy Logic-Based Robust Speed Control for an Indirect Vector-Controlled Induction Motor. Applied Sciences, 15(22), 11994. https://doi.org/10.3390/app152211994

Vancouver

Bal C. Type-3 Fuzzy Logic-Based Robust Speed Control for an Indirect Vector-Controlled Induction Motor. Applied Sciences. 2025;15(22):11994. doi:10.3390/app152211994

BibTeX
@article{Bal2025,
  author = {Bal, Cafer},
  title = {Type-3 Fuzzy Logic-Based Robust Speed Control for an Indirect Vector-Controlled Induction Motor},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {22},
  pages = {11994},
  doi = {10.3390/app152211994}
}
Kostenlos starten →