EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Assessment of the Behaviour of Ceiling Beams of Different Structure

Katarzyna Ciesielczyk, Robert Studziński, Marcin Chybiński, Jacek Ścigałło, Wojciech Szymkuć, Jakub Krzysztof Grabski, Tomasz Marciniak, Łukasz Polus

Applied Sciences · 29.10.2025 · 15 (21) · 11543

DOI: 10.3390/app152111543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 29.10.2025. Verfasst von Katarzyna Ciesielczyk und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Polish Ministry of Science and Higher Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The article focuses on floor composite beams used in buildings. Within the scope of the conducted analytical and numerical studies, the authors compared the typical solution—namely, the T-shaped reinforced concrete beam—with various types of composite beams, the height of which could not exceed the predetermined usable depth of the beam cross-section. The analyses focused on traditional steel–concrete composite beams, which are widely used in civil engineering, as well as modern solutions, such as timber–timber and steel–timber composite beams. A new type of a steel–timber composite beam with a cold-formed girder made of two channels was presented in this study. Due to the flexibility of the connections, the timber–timber and steel–timber composite beams were examined under three different connection conditions: full composite action, partial composite action, and no composite action (friction only). Composite beams with timber slabs are consistent with the principles of sustainable construction, which makes their comparison with conventional solutions particularly relevant. The load-deflection curves and the bending resistance of the analysed elements were obtained using numerical simulations. In the numerical analyses, advanced material models were used. Composite beams with timber elements had lower stiffness than the steel–concrete composite beam. For this reason, meeting the serviceability limit state can be more challenging for such structures. Furthermore, the degree of shear connection in the composite beams with timber elements had a strong impact on their load-bearing capacity and end-slip. The steel–timber composite beam with a cold-formed girder had the most favourable resistance-to-mass ratio. The analytical results, and especially the numerical findings, provide a foundation for future experimental investigations.

Förderung

  • Polish Ministry of Science and Higher Education

Zitieren

APA

Ciesielczyk, K., Studziński, R., Chybiński, M., Ścigałło, J., Szymkuć, W., Grabski, J. K., Marciniak, T., & Polus, Ł. (2025). An Assessment of the Behaviour of Ceiling Beams of Different Structure. Applied Sciences, 15(21), 11543. https://doi.org/10.3390/app152111543

Vancouver

Ciesielczyk K, Studziński R, Chybiński M, Ścigałło J, Szymkuć W, Grabski JK, et al. An Assessment of the Behaviour of Ceiling Beams of Different Structure. Applied Sciences. 2025;15(21):11543. doi:10.3390/app152111543

BibTeX
@article{Ciesielczyk2025,
  author = {Ciesielczyk, Katarzyna and Studziński, Robert and Chybiński, Marcin and Ścigałło, Jacek and Szymkuć, Wojciech and Grabski, Jakub Krzysztof and Marciniak, Tomasz and Polus, Łukasz},
  title = {An Assessment of the Behaviour of Ceiling Beams of Different Structure},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {21},
  pages = {11543},
  doi = {10.3390/app152111543}
}