EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity, Reliability, and Sensitivity of the Brazilian Jiu-Jitsu Cardiorespiratory Fitness Test: A Methodological Approach Based on Combat Specificity

Eduardo Báez-San Martín, Marcelo Tuesta, Claudio Nieto-Jimenez, Alex Ojeda-Aravena, Daniel Rojas-Valverde, Rodrigo Yáñez-Sepúlveda, Ildefonso Alvear-Ordenes

Applied Sciences · 16.10.2025 · 15 (20) · 11124

DOI: 10.3390/app152011124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.10.2025. Verfasst von Eduardo Báez-San Martín und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Brazilian jiu-jitsu (BJJ) is a combat sport that requires intermittent high-intensity actions, strong technical skills, strength, and aerobic capacity. Yet, there is limited evidence of validated sport-specific field protocols. This study aimed to determine the validity, reliability, and sensitivity of the BJJ Cardiorespiratory Fitness Test (BJJ-CRFT). Twenty-three trained practitioners (20 men and 3 women; age 34.4 ± 7.6 years) performed a cardiopulmonary exercise test on a treadmill and completed the BJJ-CRFT on two occasions, one week apart. Construct validity was examined using receiver operating characteristic (ROC) analysis, while concurrent validity was tested against maximal oxygen uptake (VO2max) and maximal aerobic speed (MAS). Intra-session reliability was determined through the intraclass correlation coefficient (ICC) and the coefficient of variation (CV%). Main results showed a good discriminative ability (ROC: 0.82; 95% CI: 0.64–0.99, p = 0.001). Total repetitions in the BJJ-CRFT showed a large positive correlation with VO2max (r = 0.66; 95% CI: 0.35–0.85, p = 0.0006) and a very large positive correlation with MAS (r = 0.72; 95% CI: 0.44–0.87, p = 0.0001). Key performance metrics, including guard passes and test duration, demonstrated excellent relative reliability (ICC = 0.99) and good absolute reliability (CV% = 4.4% and 3.6%), being sensitive to small changes. These results confirm that the BJJ-CRFT is a valid, reliable, and sensitive field test for monitoring aerobic adaptations and guiding training prescription in BJJ.

Zitieren

APA

Martín, E. B., Tuesta, M., Nieto-Jimenez, C., Ojeda-Aravena, A., Rojas-Valverde, D., Yáñez-Sepúlveda, R., & Alvear-Ordenes, I. (2025). Validity, Reliability, and Sensitivity of the Brazilian Jiu-Jitsu Cardiorespiratory Fitness Test: A Methodological Approach Based on Combat Specificity. Applied Sciences, 15(20), 11124. https://doi.org/10.3390/app152011124

Vancouver

Martín EB, Tuesta M, Nieto-Jimenez C, Ojeda-Aravena A, Rojas-Valverde D, Yáñez-Sepúlveda R, et al. Validity, Reliability, and Sensitivity of the Brazilian Jiu-Jitsu Cardiorespiratory Fitness Test: A Methodological Approach Based on Combat Specificity. Applied Sciences. 2025;15(20):11124. doi:10.3390/app152011124

BibTeX
@article{Martn2025,
  author = {Martín, Eduardo Báez-San and Tuesta, Marcelo and Nieto-Jimenez, Claudio and Ojeda-Aravena, Alex and Rojas-Valverde, Daniel and Yáñez-Sepúlveda, Rodrigo and Alvear-Ordenes, Ildefonso},
  title = {Validity, Reliability, and Sensitivity of the Brazilian Jiu-Jitsu Cardiorespiratory Fitness Test: A Methodological Approach Based on Combat Specificity},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {20},
  pages = {11124},
  doi = {10.3390/app152011124}
}
Kostenlos starten →