EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Contact Heart Rate Monitoring Method Based on Multi-Source Data Fusion

Qinwei Li, Zhongxun Teng, Yuping Shi, Guang Zhang, Ming Yu

Applied Sciences · 21.08.2025 · 15 (16) · 9189

DOI: 10.3390/app15169189 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 21.08.2025. Verfasst von Qinwei Li und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tianjin Education Commission.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes a non-contact heart rate long-time monitoring system based on multi-source data fusion. Microwave radar cannot associate the identity of a target with its signal, whereas rPPG can achieve this through facial recognition. Additionally, rPPG technology is unable to monitor heart rate in completely dark environments, while visible light is not a prerequisite for radar-based heart rate monitoring. Consequently, this paper proposes a method for heart rate monitoring that fuses microwave and video data. The methodology involves preprocessing both microwave and video data, extracting specific features of different types of data, and identifying the heart rate by the signal features. In the experiments, the identification accuracy for heart rates ranging from 57 to 171 bpm was 73.1%, with accuracies of 75.8% for heart rates below 60 bpm and 89.9% for heart rates above 120 bpm. Compared to single-source data, the accuracy increased by 25.4% and 28.6%, respectively. The monitoring duration is approximately 30 s and achieves model optimization through algorithm deployment. These results validate the effectiveness and timeliness of the proposed method.

Förderung

  • Tianjin Education Commission

Zitieren

APA

Li, Q., Teng, Z., Shi, Y., Zhang, G., & Yu, M. (2025). Non-Contact Heart Rate Monitoring Method Based on Multi-Source Data Fusion. Applied Sciences, 15(16), 9189. https://doi.org/10.3390/app15169189

Vancouver

Li Q, Teng Z, Shi Y, Zhang G, Yu M. Non-Contact Heart Rate Monitoring Method Based on Multi-Source Data Fusion. Applied Sciences. 2025;15(16):9189. doi:10.3390/app15169189

BibTeX
@article{Li2025,
  author = {Li, Qinwei and Teng, Zhongxun and Shi, Yuping and Zhang, Guang and Yu, Ming},
  title = {Non-Contact Heart Rate Monitoring Method Based on Multi-Source Data Fusion},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {16},
  pages = {9189},
  doi = {10.3390/app15169189}
}
Kostenlos starten →