EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Structural Optimization of a Pipeline Savonius Hydro Turbine Based on Broad Learning

Xingxiang Liu, Jing Hu, Yao Zhang, He Yu, Wenfeng Shen, Yiming Xu, Jieqing Zheng

Applied Sciences · 20.08.2025 · 15 (16) · 9181

DOI: 10.3390/app15169181 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 20.08.2025. Verfasst von Xingxiang Liu und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Xiamen, Natural Science Foundation of Fujian Province, Scientific Research Foundation of JiMei University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Utilizing pipeline Savonius hydro turbines driven by the pressure difference in water flow in the irrigation pipelines to generate electricity can achieve stable and reliable charging of the sensor battery, thereby addressing autonomous energy supply concerns. However, due to the low energy capture efficiency of the Savonius turbine with a small pressure difference, it is necessary to optimally design the internal flow channel structure to improve its efficiency and achieve a more miniaturized overall equipment, which has extremely high engineering application value. This study investigates the Savonius turbine, installed within the irrigation pipeline operating under specific conditions (diameter: 60 mm; flow rate: 15 m3/h; inlet pressure: 0.2 MPa; outlet pressure ≤ 0.05 MPa). A validated Computational Fluid Dynamics numerical model was developed to generate 200 datasets for a subsequent structural optimization process utilizing a Bayesian-optimized broad learning technique. The optimal structural parameters for maximum efficiency are a deflector angle of 10°, an aspect ratio of 0.775, and three blades, resulting in a maximum efficiency of 21.73% at a rotational speed of 1098 r/min. For the maximum power coefficient, the optimal combination is a deflector angle of 10°, a height-to-diameter ratio of 0.9, and three blades, yielding a peak power coefficient of 0.1859 at a rotational speed of 600 r/min.

Förderung

  • Natural Science Foundation of Xiamen
  • Natural Science Foundation of Fujian Province
  • Scientific Research Foundation of JiMei University

Zitieren

APA

Liu, X., Hu, J., Zhang, Y., Yu, H., Shen, W., Xu, Y., & Zheng, J. (2025). Structural Optimization of a Pipeline Savonius Hydro Turbine Based on Broad Learning. Applied Sciences, 15(16), 9181. https://doi.org/10.3390/app15169181

Vancouver

Liu X, Hu J, Zhang Y, Yu H, Shen W, Xu Y, et al. Structural Optimization of a Pipeline Savonius Hydro Turbine Based on Broad Learning. Applied Sciences. 2025;15(16):9181. doi:10.3390/app15169181

BibTeX
@article{Liu2025,
  author = {Liu, Xingxiang and Hu, Jing and Zhang, Yao and Yu, He and Shen, Wenfeng and Xu, Yiming and Zheng, Jieqing},
  title = {Structural Optimization of a Pipeline Savonius Hydro Turbine Based on Broad Learning},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {16},
  pages = {9181},
  doi = {10.3390/app15169181}
}
Kostenlos starten →