Optimization of Impedance-Based Real-Time Assay in xCELLigence RTCA SP16 Device for the Analysis of Fully Differentiated Caco-2 Cells
Applied Sciences · 25.07.2025 · 15 (15) · 8298
DOI: 10.3390/app15158298 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 25.07.2025. Verfasst von Nadia Khan und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Priority Research Area qLife under the program “Excellence Initiative—Research University” at the Jagiellonian University in Krakow, Jagiellonian University Medical College.
Abstract (Originalsprache)
Impedance-based cellular assays allow determination of biological functions of cell populations in real-time by measuring electrical impedance. As compared to end-point assays, such as trans-epithelial electrical resistance assays, for example, they enable fast, non-invasive, and easy detection of cell kinetics—their growth, attachment, and interaction can be monitored over time. In our experiment, Caco-2 cells were cultured on E-plates 16. Next, fully differentiated cells were treated with either TNF-α or 3,4-dihydroxy-L-phenylalanine (L-DOPA). We aimed to verify the possibility of real-time testing of the viability, monolayer formation, and integrity (i.e., the presence of a functional and polarized monolayer) of Caco-2 cells by the xCELLigence real-time cell analyzer (RTCA) S16 system (Agilent Technologies).
Förderung
- Priority Research Area qLife under the program “Excellence Initiative—Research University” at the Jagiellonian University in Krakow
- Jagiellonian University Medical College
Zitieren
APA
Khan, N., Kurnik-Łucka, M., Kudrycka, M., Gil, K., & Latacz, G. (2025). Optimization of Impedance-Based Real-Time Assay in xCELLigence RTCA SP16 Device for the Analysis of Fully Differentiated Caco-2 Cells. Applied Sciences, 15(15), 8298. https://doi.org/10.3390/app15158298
Vancouver
Khan N, Kurnik-Łucka M, Kudrycka M, Gil K, Latacz G. Optimization of Impedance-Based Real-Time Assay in xCELLigence RTCA SP16 Device for the Analysis of Fully Differentiated Caco-2 Cells. Applied Sciences. 2025;15(15):8298. doi:10.3390/app15158298
BibTeX
@article{Khan2025,
author = {Khan, Nadia and Kurnik-Łucka, Magdalena and Kudrycka, Maja and Gil, Krzysztof and Latacz, Gniewomir},
title = {Optimization of Impedance-Based Real-Time Assay in xCELLigence RTCA SP16 Device for the Analysis of Fully Differentiated Caco-2 Cells},
journal = {Applied Sciences},
year = {2025},
volume = {15},
number = {15},
pages = {8298},
doi = {10.3390/app15158298}
}