Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed
Applied Sciences · 17.05.2025 · 15 (10) · 5612
DOI: 10.3390/app15105612 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.05.2025. Verfasst von Yuexiang Du und 6 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Mongkut’s Institute of Technology, Ladkrabang, NSRF.
Abstract (Originalsprache)
This article reports the effect of twisted tapes with continuous V-ribs on the thermal performance index characteristics of a heat exchanger tube. Numerical and experimental studies were conducted to investigate the influence of V-rib attack angles (β = 15°, 30°, and 45°) in forward and backward arrangements. This investigation employed 0.9 mm thick, continuous V-rib twisted tapes (CVRTs) made from aluminum sheets formed with a twist ratio of y/w = 4.0. The experimental results indicated that a continuous V-rib twisted tape (CVRT) was more effective in heat transfer improvement than a typical twisted tape (TT). This was due to swirl and longitudinal vortex flows that helped increase flow mixing and reduce boundary layer thickness. Decreased V-rib attack angles (β) led to greater heat transfer enhancement, pressure drop, and thermal performance index values due to the greater turbulent mixing of fluid. The numerical result revealed that a continuous V-rib twisted tape created strong longitudinal vortex flow, especially with higher attack angles. The Turbulent Kinetic Energy (TKE) and core fluid temperature increased with the insertion of CVRTs. Local Nusselt numbers also remained relatively high for heat exchanger tubes with CVRTs. The experimental study illustrated that a tube with a CVRT installed augmented heat transfer. In the experimentally studied cases, a backward arrangement had more heat transfer, a greater friction factor, and a better thermal performance index. Compared to a plain tube, a tube with CVRT installed, having β = 15°, 30°, and 45°, showed 76.8, 71.6, and 66.2% improved heat transfer, respectively. CVRTs with these three β-values, respectively, exhibited higher thermal performance than a TT. Among the investigated CVRTs, the backward-arranged tape with β = 15° offered the maximum thermal performance index, 1.13 at Re = 6000. The results are congruent with the simulation outcomes, hence supporting the CFD analysis.
Förderung
- King Mongkut’s Institute of Technology, Ladkrabang
- NSRF
Zitieren
APA
Du, Y., Wongcharee, K., Chuwattanakul, V., Naphon, P., Maruyama, N., Hirota, M., & Eiamsa-ard, S. (2025). Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed. Applied Sciences, 15(10), 5612. https://doi.org/10.3390/app15105612
Vancouver
Du Y, Wongcharee K, Chuwattanakul V, Naphon P, Maruyama N, Hirota M, et al. Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed. Applied Sciences. 2025;15(10):5612. doi:10.3390/app15105612
BibTeX
@article{Du2025,
author = {Du, Yuexiang and Wongcharee, Khwanchit and Chuwattanakul, Varesa and Naphon, Paisarn and Maruyama, Naoki and Hirota, Masafumi and Eiamsa-ard, Smith},
title = {Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed},
journal = {Applied Sciences},
year = {2025},
volume = {15},
number = {10},
pages = {5612},
doi = {10.3390/app15105612}
}
EUVIMED