EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Compact Design and Impact Ionization: Utilizing Small-Sized Thyristors in a 4-Stage Marx Generator

Alicia del Barrio Montañés, Viliam Senaj, Thomas Kramer, Georg Müller, Martin Sack

Applied Sciences · 17.03.2025 · 15 (6) · 3289

DOI: 10.3390/app15063289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.03.2025. Verfasst von Alicia del Barrio Montañés und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wolfgang Gentner Programme of the German Federal Ministry of Education and Research.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In CERN’s beam transfer lines, high-voltage generators have traditionally relied on thyratron switches; however, thyratrons present operational challenges and are also becoming increasingly hard to source. To address this issue, there is a growing interest in adopting compact pulse generators made from commercially available off-the-shelf (COTS) components. Recent research has demonstrated that thyristors designed for rectifier applications, which are not specifically designed for fast rise times, can be activated in overvoltage mode—also referred to as impact-ionization mode. These devices achieve substantial improvements in their dU/dt and dI/dt characteristics. This activation method involves applying a substantial overvoltage between the thyristor’s anode and cathode, along with a fast slew rate exceeding 1 kV/ns. The adoption of compact pulse generators built from COTS components opens up new opportunities for deploying this technology across multiple domains, including high-speed kicker generators in particle accelerators. In our methodology, we incorporated commercially available high-voltage components—SiC MOSFETs—that were triggered using a fast gate driver, which was custom-designed. The generated output pulse was then amplified and sharpened in a four-stage Marx generator composed of small, 1.2 kV rated D2PAK thyristors. This configuration yielded an output pulse with an amplitude of 11 kV and a 10–90% dU/dt of 13.3 kV/ns. The present study details the design of the Marx generator and the resulting pulses, along with the challenges faced in high-voltage measurements.

Förderung

  • Wolfgang Gentner Programme of the German Federal Ministry of Education and Research

Zitieren

APA

Montañés, A. D. B., Senaj, V., Kramer, T., Müller, G., & Sack, M. (2025). Compact Design and Impact Ionization: Utilizing Small-Sized Thyristors in a 4-Stage Marx Generator. Applied Sciences, 15(6), 3289. https://doi.org/10.3390/app15063289

Vancouver

Montañés ADB, Senaj V, Kramer T, Müller G, Sack M. Compact Design and Impact Ionization: Utilizing Small-Sized Thyristors in a 4-Stage Marx Generator. Applied Sciences. 2025;15(6):3289. doi:10.3390/app15063289

BibTeX
@article{Montas2025,
  author = {Montañés, Alicia del Barrio and Senaj, Viliam and Kramer, Thomas and Müller, Georg and Sack, Martin},
  title = {Compact Design and Impact Ionization: Utilizing Small-Sized Thyristors in a 4-Stage Marx Generator},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {3289},
  doi = {10.3390/app15063289}
}
Kostenlos starten →