EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Self-Adaptive Transtibial Prosthesis: Automatic Detection and Compensation of Leg Length Discrepancy

Dimitrie Cristian Fodor, Dragoș Florin Chitariu, Cristian Aghion, Neculai Eugen Seghedin

Applied Sciences · 17.03.2025 · 15 (6) · 3247

DOI: 10.3390/app15063247 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.03.2025. Verfasst von Dimitrie Cristian Fodor und 3 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: “National Research Grants—ARUT” program of the Technical University “Gheorghe Asachi” of Iasi, Romania.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite the development of manual and passive mechanisms for adjusting prosthesis length, their efficiency remains limited, and users continue to face challenges related to leg length discrepancy (LLD). This dysfunction is an unresolved issue in prosthetics, and the lack of a prosthesis capable of automatically correcting LLD highlights a critical gap in the field.

Methods

This study introduces a transtibial self-adaptive prosthesis capable of autonomously compensating for LLD. The prosthesis’s performance was evaluated using the ARAMIS 3D Digital Image Correlation (DIC) system, which monitored the displacement of markers strategically placed on a test mannequin in a strategic manner. Simulated LLDs were generated by inserting standardized plates beneath the mannequin’s intact limb.

Results

The proposed prosthesis demonstrated efficient compensation of simulated LLD, with a mean relative error of 8.8% for a 1 mm simulation and 7.2% for a 10 mm simulation. The DIC system highlighted the rapidity and precision of the prosthesis mechanism in adjusting its length to eliminate LLD.

Conclusions

The proposed transtibial self-adaptive prosthesis represents a significant advancement in the automatic correction of LLD, enhancing gait symmetry and user stability. The results suggest substantial potential for clinical applications, with promising implications for users of unilateral prostheses.

Förderung

  • “National Research Grants—ARUT” program of the Technical University “Gheorghe Asachi” of Iasi, Romania

Zitieren

APA

Fodor, D. C., Chitariu, D. F., Aghion, C., & Seghedin, N. E. (2025). Self-Adaptive Transtibial Prosthesis: Automatic Detection and Compensation of Leg Length Discrepancy. Applied Sciences, 15(6), 3247. https://doi.org/10.3390/app15063247

Vancouver

Fodor DC, Chitariu DF, Aghion C, Seghedin NE. Self-Adaptive Transtibial Prosthesis: Automatic Detection and Compensation of Leg Length Discrepancy. Applied Sciences. 2025;15(6):3247. doi:10.3390/app15063247

BibTeX
@article{Fodor2025,
  author = {Fodor, Dimitrie Cristian and Chitariu, Dragoș Florin and Aghion, Cristian and Seghedin, Neculai Eugen},
  title = {Self-Adaptive Transtibial Prosthesis: Automatic Detection and Compensation of Leg Length Discrepancy},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {3247},
  doi = {10.3390/app15063247}
}
Kostenlos starten →