EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller

Ayan Sengupta, Paride Gullo, Vahid Khorshidi, Mani Sankar Dasgupta

Applied Sciences · 10.03.2025 · 15 (6) · 2955

DOI: 10.3390/app15062955 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 10.03.2025. Verfasst von Ayan Sengupta und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The subcooling potential of a novel R717-based waste heat-driven multi-ejector chiller (HEC) integrated with an R744 refrigeration system was evaluated for use in supermarkets. The performance was compared with an R744 refrigeration system coupled to R718- and R600a-based HECs, an R744 system equipped with parallel compression (PC), and a standard R744 booster system (CB) in various warm and hot climatic locations. Integration of the R717-based HEC was found to improve the coefficient of performance by 3.7% at 27 °C to 12.1% at 45 °C compared to the R718, and by 1.6% at 27 °C to 7.6% at 45 °C compared to the R600a-based system. The energy-saving potential of the R717 system (6.2% to 9.4%) was also found to be higher than that of the R718 (0.7% to 2.8%) and R600a systems (2.5% to 6.6%). The use of the existing high-pressure controllers of the CB system was found to impose a relatively lower penalty on the system performance compared to the controllers of the PC system. Although the integration of the R718 system incurred a significantly lower additional investment, the recovery time of the R600a-based HEC (2.3–4.8 years) was found to be the shortest.

Zitieren

APA

Sengupta, A., Gullo, P., Khorshidi, V., & Dasgupta, M. S. (2025). Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller. Applied Sciences, 15(6), 2955. https://doi.org/10.3390/app15062955

Vancouver

Sengupta A, Gullo P, Khorshidi V, Dasgupta MS. Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller. Applied Sciences. 2025;15(6):2955. doi:10.3390/app15062955

BibTeX
@article{Sengupta2025,
  author = {Sengupta, Ayan and Gullo, Paride and Khorshidi, Vahid and Dasgupta, Mani Sankar},
  title = {Transcritical R744 Supermarket Refrigeration System Integrated with a Heat-Driven Ejector Chiller},
  journal = {Applied Sciences},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {2955},
  doi = {10.3390/app15062955}
}
Kostenlos starten →