Design of NO2 Photoacoustic Detection System Based on Finite Element Simulation
Applied Sciences · 05.12.2024 · 14 (23) · 11343
DOI: 10.3390/app142311343 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 05.12.2024. Verfasst von Long Wu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Open Fund of State Key Laboratory for Mining Response and Disaster Prevention and Control of Deep Coal Mines, Anhui Province Joint Key Laboratory of Human Machine Collaborative Robots.
Abstract (Originalsprache)
Based on photoacoustic spectroscopy and finite element simulation technology, a simulation model of sound field excitation in a cylindrical resonant photoacoustic cell was established. The finite element simulation method was used to analyze the acoustic mode and sound pressure distribution of the cavity structure of the photoacoustic cell. The effects of the geometric parameters of the resonator and the buffer cavity on the performance of the photoacoustic cell were compared. The frequency response characteristics of the photoacoustic cell and the effects of the air intake and the air outlet were studied. Based on the simulation results, a cylindrical resonant photoacoustic cell was designed, and a photoacoustic sensor for NO2 detection was built. NO2 with a volume fraction of 10−5 was taken as the sample gas through frequency scanning to obtain the frequency response curve of the system. The resonant frequency is 1730 Hz, and the cell constant is about 542.3 (Pa*cm)/W. The quality factor is 10.05. By linear fitting the calibration curve of the sensor, the fitting slope is 0.012 µV/ppb, and R2 is 0.998. Atmospheric NO2 detection was carried out for two consecutive weeks, whose findings are in good agreement with the data released by a Huainan environmental monitoring site. The experimental results show that the system can detect NO2 in the atmosphere with high sensitivity.
Förderung
- Open Fund of State Key Laboratory for Mining Response and Disaster Prevention and Control of Deep Coal Mines
- Anhui Province Joint Key Laboratory of Human Machine Collaborative Robots
Zitieren
APA
Wu, L., Chen, T., Xiang, B., & Xing, L. (2024). Design of NO2 Photoacoustic Detection System Based on Finite Element Simulation. Applied Sciences, 14(23), 11343. https://doi.org/10.3390/app142311343
Vancouver
Wu L, Chen T, Xiang B, Xing L. Design of NO2 Photoacoustic Detection System Based on Finite Element Simulation. Applied Sciences. 2024;14(23):11343. doi:10.3390/app142311343
BibTeX
@article{Wu2024,
author = {Wu, Long and Chen, Tao and Xiang, Biao and Xing, Likun},
title = {Design of NO2 Photoacoustic Detection System Based on Finite Element Simulation},
journal = {Applied Sciences},
year = {2024},
volume = {14},
number = {23},
pages = {11343},
doi = {10.3390/app142311343}
}