Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 17.11.2024. Verfasst von Corrado Chisari und 4 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union-Next Generation EU, MUR (Ministry of University and Research).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The seismic assessment of historical masonry bell towers is of significant interest, particularly in Italy, due to their widespread presence and inherent vulnerability given by their slenderness. According to technical codes and standard practice, the seismic evaluation of masonry bell towers can be conducted using a range of methodologies that vary in their level of detail. This paper presents a case study of a historical masonry bell tower located in the Caserta Province (Italy). Extensive investigative efforts were undertaken to determine the tower’s key geometric and structural characteristics, as well as to document ongoing damage phenomena. The dynamic behavior of the tower was assessed through ambient vibration testing, which enabled the identification of the principal modal shapes and corresponding frequencies, also highlighting peculiar dynamical characteristics caused by the damage conditions. Subsequently, the seismic assessment was carried out using both Level 1 (simplified mechanical) and Level 2 (kinematic limit analysis) methodologies. This assessment helped identify the most probable collapse mechanisms and laid the foundation for employing more advanced methodologies to design necessary retrofitting interventions. The study emphasizes the importance of Level 2 analyses for structures where out-of-plane failure mechanisms are likely due to pre-existing cracking. Both approaches provide less-than-unity acceleration factors, ranging from 0.45 for Level 1 (assuming non-ductile behavior) to 0.59 for Level 2, in this case specifically using the information available about existing cracking pattern.

Förderung

  • European Union-Next Generation EU
  • MUR (Ministry of University and Research)

Zitieren

APA

Chisari, C., Zizi, M., Lavino, A., Freda, S., & Matteis, G. D. (2024). Operational Modal Analysis and Safety Assessment of a Historical Masonry Bell Tower. Applied Sciences, 14(22), 10604. https://doi.org/10.3390/app142210604

Vancouver

Chisari C, Zizi M, Lavino A, Freda S, Matteis GD. Operational Modal Analysis and Safety Assessment of a Historical Masonry Bell Tower. Applied Sciences. 2024;14(22):10604. doi:10.3390/app142210604

BibTeX
@article{Chisari2024,
  author = {Chisari, Corrado and Zizi, Mattia and Lavino, Angelo and Freda, Salvatore and Matteis, Gianfranco De},
  title = {Operational Modal Analysis and Safety Assessment of a Historical Masonry Bell Tower},
  journal = {Applied Sciences},
  year = {2024},
  volume = {14},
  number = {22},
  pages = {10604},
  doi = {10.3390/app142210604}
}
Kostenlos starten →