EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Full-Field Dynamic Deflection Measurement of Beams Based on Dense Feature Matching and Mismatch Removal Method

Jiayan Zheng, Yichen Tang, Haijing Liu, Zhixiang Zhou, Ji He

Applied Sciences · 16.04.2024 · 14 (8) · 3347

DOI: 10.3390/app14083347 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.04.2024. Verfasst von Jiayan Zheng und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, the Joint Training Base for Postgraduate Construction Project of Chongqing, the Postgraduate Tutor Team Construction Project of Chongqing.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To solve the problems of measurement errors led by mismatches of dense feature matching in machine vision structural deflection measurement, this paper proposes a dense feature extraction, matching, and dual-step mismatch-removal-based full-field structural dynamic deflection measurement method. First, the of dense feature detection and matching theory is introduced to extract the SIFT feature points on a structural surface in an image sequence and matched by FLANN to trace the structure movement, and the mechanisms and causes of mismatches are analyzed. Then, a dual-step mismatch removal method combining RANSAC and Structural Displacement Continuity Restriction (SDCR) is introduced to achieve full-field dynamic beam deflection measurement. The proposed method is validated through indoor cantilever beam experiments, and results show that the method can effectively eliminate a large number of SIFT feature mismatches (accounting for approximately 55% of the total matched feature points). The full-field dynamic displacement field of the beam can be measured with the correctly matched dense feature points by converting dense feature point displacements into continuous and uniform spatiotemporal deflections of the structure. A comparison with the GOM Correlate Professional DIC measurement system was conducted, and the maximum measurement error of the cantilever beam dynamic displacement of the proposed method is between 0.024 and 0.053 mm, the root mean squared error of displacement is approximately 0.01 mm, and the correlation coefficient between two deflection–time curves reaches 0.9964. The proposed algorithm is proven to be effective in full-field displacement measurement and has great potential in future structural health monitoring of bridges.

Förderung

  • the National Natural Science Foundation of China
  • the Joint Training Base for Postgraduate Construction Project of Chongqing
  • the Postgraduate Tutor Team Construction Project of Chongqing

Zitieren

APA

Zheng, J., Tang, Y., Liu, H., Zhou, Z., & He, J. (2024). Research on Full-Field Dynamic Deflection Measurement of Beams Based on Dense Feature Matching and Mismatch Removal Method. Applied Sciences, 14(8), 3347. https://doi.org/10.3390/app14083347

Vancouver

Zheng J, Tang Y, Liu H, Zhou Z, He J. Research on Full-Field Dynamic Deflection Measurement of Beams Based on Dense Feature Matching and Mismatch Removal Method. Applied Sciences. 2024;14(8):3347. doi:10.3390/app14083347

BibTeX
@article{Zheng2024,
  author = {Zheng, Jiayan and Tang, Yichen and Liu, Haijing and Zhou, Zhixiang and He, Ji},
  title = {Research on Full-Field Dynamic Deflection Measurement of Beams Based on Dense Feature Matching and Mismatch Removal Method},
  journal = {Applied Sciences},
  year = {2024},
  volume = {14},
  number = {8},
  pages = {3347},
  doi = {10.3390/app14083347}
}
Kostenlos starten →