EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electron Absorbed Fractions and S Factors for Intermediate Size Target Volumes: Comparison of Analytic Calculations and Monte Carlo Simulations

Christina Kotroumpelou, Ioanna Kyriakou, Vladimir Ivanchenko, Sebastien Incerti, Dimitris Emfietzoglou

Applied Sciences · 08.03.2024 · 14 (6) · 2275

DOI: 10.3390/app14062275 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 08.03.2024. Verfasst von Christina Kotroumpelou und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The absorbed fraction and the S factor represent fundamental quantities in MIRD-based dosimetry of radiopharmaceutical therapy (RPT). Although Monte Carlo (MC) simulations represent the gold standard in RPT dosimetry, dose point kernels (DPK) obtained from analytic range–energy relations offer a more practical alternative for charged-particle dosimetry (β- or α-emitters). In this work, we perform DPK- and MC-based calculations of the self-absorbed fractions and S factors for monoenergetic electrons uniformly distributed in intermediate-size target volumes (~mm to cm) relevant to micrometastasis and disseminated disease. Specifically, the aim of the present work is as follows: (i) the development of an analytic range–energy relation, effective over a broad energy range (100 keV–20 MeV) covering most applications of radiotherapeutic interest; (ii) the application of the new formula to DPK-based calculations of the absorbed fraction and S factor and comparison against MC simulations (both published and present work data) as well as the MIRDcell V2.0.16 software, which uses a similar analytic methodology; and (iii) the study of the influence of simulation parameters (step-size, tracking/production cut-off energies, and ionization model) in Geant4-based calculations of S factors. It is shown that the present DPK-based calculations are in excellent agreement (within 1.5%) with the MIRDcell software, while also being in fair agreement with published MC data as well as with the new Geant4 simulations, with average differences of ~20% for the (sub) mm-sized volumes and ~10% for the cm-sized volumes. The effect of the choice of Geant4 simulation parameters was found to be negligible for the examined target volumes (~mm), except for the use of the Penelope ionization model, which may exhibit noticeable discrepancies (up to ~20%) against the Standard and Livermore models. The present work provides quantitative information that may be useful to both the MC- and DPK-based beta dosimetry of micrometastasis and disseminated disease, which represents an important field of application of RPT.

Zitieren

APA

Kotroumpelou, C., Kyriakou, I., Ivanchenko, V., Incerti, S., & Emfietzoglou, D. (2024). Electron Absorbed Fractions and S Factors for Intermediate Size Target Volumes: Comparison of Analytic Calculations and Monte Carlo Simulations. Applied Sciences, 14(6), 2275. https://doi.org/10.3390/app14062275

Vancouver

Kotroumpelou C, Kyriakou I, Ivanchenko V, Incerti S, Emfietzoglou D. Electron Absorbed Fractions and S Factors for Intermediate Size Target Volumes: Comparison of Analytic Calculations and Monte Carlo Simulations. Applied Sciences. 2024;14(6):2275. doi:10.3390/app14062275

BibTeX
@article{Kotroumpelou2024,
  author = {Kotroumpelou, Christina and Kyriakou, Ioanna and Ivanchenko, Vladimir and Incerti, Sebastien and Emfietzoglou, Dimitris},
  title = {Electron Absorbed Fractions and S Factors for Intermediate Size Target Volumes: Comparison of Analytic Calculations and Monte Carlo Simulations},
  journal = {Applied Sciences},
  year = {2024},
  volume = {14},
  number = {6},
  pages = {2275},
  doi = {10.3390/app14062275}
}
Kostenlos starten →