EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Operator and Patient Doses after Irradiation with Handheld X-ray Devices

Ali Altındağ, Hakan Eren, Kaan Orhan, Sebahat Görgün

Applied Sciences · 18.09.2023 · 13 (18) · 10414

DOI: 10.3390/app131810414 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 18.09.2023. Verfasst von Ali Altındağ und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ankara University Scientific Research Projects Coordination Unit.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate radiation doses from handheld X-ray devices, specifically NOMAD Pro 2TM (DvcN), Rextar X (DvcRX), and Diox 602 (DvcD), targeting operator and patient’s critical organs and tissues. Calibrated TLD-100H dosimeters were placed on a mannequin and phantom head, focusing on the eyes, thyroid, gonads, hands, and salivary glands. Using a TLD reader, absorbed equivalent doses post irradiation were assessed. Conventional systems yielded higher radiation doses than phosphor plates and digital systems. Notably, implementing protective measures resulted in significant (p < 0.05) dose reductions to the operator. Peak measurements without protection included: gonad 24.4 (DvcN) μGy; thyroid 30.5 (DvcN) μGy; right eye 31.9 (DvcN) μGy; left eye 27.9 (DvcN) μGy; right hand 111.6 (DvcRX) μGy; and left hand 71.7 (DvcD) μGy. Radiation dose reductions ranged from 11.49% to 93.25%, depending on the region and device. It is imperative to adhere to radiological protection protocols, particularly when employing handheld X-ray devices; optimally, these should be used with digital systems.

Förderung

  • Ankara University Scientific Research Projects Coordination Unit

Zitieren

APA

Altındağ, A., Eren, H., Orhan, K., & Görgün, S. (2023). Evaluation of Operator and Patient Doses after Irradiation with Handheld X-ray Devices. Applied Sciences, 13(18), 10414. https://doi.org/10.3390/app131810414

Vancouver

Altındağ A, Eren H, Orhan K, Görgün S. Evaluation of Operator and Patient Doses after Irradiation with Handheld X-ray Devices. Applied Sciences. 2023;13(18):10414. doi:10.3390/app131810414

BibTeX
@article{Altnda2023,
  author = {Altındağ, Ali and Eren, Hakan and Orhan, Kaan and Görgün, Sebahat},
  title = {Evaluation of Operator and Patient Doses after Irradiation with Handheld X-ray Devices},
  journal = {Applied Sciences},
  year = {2023},
  volume = {13},
  number = {18},
  pages = {10414},
  doi = {10.3390/app131810414}
}
Kostenlos starten →