Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 27.04.2023. Verfasst von Chi Zhang und 8 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program, National Natural Science Foundation, Youth Innovation Promotion Association.
Abstract (Originalsprache)
An online automatic feedback system has been successfully installed and commissioned at the BL08U1A Soft X-ray Spectromicroscopy Beamline of Shanghai Synchrotron Radiation Facility, which can monitor the incident X-ray beam in real time by measuring the blade-edge signals of the exit slit and automatically adjust the elliptical cylindrical mirror parameters to achieve beam calibration and maintain the optimal X-ray flux of the sample. This work provides a comprehensive description of the hardware composition, system implementation, feedback logic, function and software design, system optimization and commission, as well as the online experimental results supported by the system. The experimental results demonstrated that the online automatic feedback system is capable of effectively maintaining the optimal X-ray beam flux for X-ray absorption spectroscopy experiments. Its success can provide valuable technique assistance for the design, construction and optimization of similar systems at various beamlines in synchrotron sources in the future.
Förderung
- National Key Research and Development Program
- National Natural Science Foundation
- Youth Innovation Promotion Association
Zitieren
APA
Zhang, C., Liu, H., Wang, C., Guo, Z., Zhang, X., Xu, Z., Zhen, X., Wang, Y., & Tai, R. (2023). Automatic Feedback System for X-ray Flux at BL08U1A Soft X-ray Spectromicroscopy Beamline of Shanghai Synchrotron Radiation Facility. Applied Sciences, 13(9), 5456. https://doi.org/10.3390/app13095456
Vancouver
Zhang C, Liu H, Wang C, Guo Z, Zhang X, Xu Z, et al. Automatic Feedback System for X-ray Flux at BL08U1A Soft X-ray Spectromicroscopy Beamline of Shanghai Synchrotron Radiation Facility. Applied Sciences. 2023;13(9):5456. doi:10.3390/app13095456
BibTeX
@article{Zhang2023,
author = {Zhang, Chi and Liu, Haigang and Wang, Chunpeng and Guo, Zhi and Zhang, Xiangzhi and Xu, Zijian and Zhen, Xiangjun and Wang, Yong and Tai, Renzhong},
title = {Automatic Feedback System for X-ray Flux at BL08U1A Soft X-ray Spectromicroscopy Beamline of Shanghai Synchrotron Radiation Facility},
journal = {Applied Sciences},
year = {2023},
volume = {13},
number = {9},
pages = {5456},
doi = {10.3390/app13095456}
}
EUVIMED