EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Technique for Multi-Parameter Signal Processing of an Eddy-Current Probe for Measuring the Thickness of Non-Conductive Coatings on Non-Magnetic Electrically Conductive Base Metals

Michael Syasko, Pavel Solomenchuk, Igor’ Soloviev, Natalia Ampilova

Applied Sciences · 20.04.2023 · 13 (8) · 5144

DOI: 10.3390/app13085144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 20.04.2023. Verfasst von Michael Syasko und 3 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The known amplitude-sensitive eddy-current method for measuring the thickness of non-conductive coatings on conductive non-magnetic base metals does not satisfy the accuracy requirements. A primary consideration is the significant influence of a change in the specific electrical conductivity of the base metals on results of measurements. In this study, we developed a technique for measuring the thickness of non-conductive coatings on non-magnetic conductive base metals by using the eddy-current amplitude-phase method and implemented algorithms to process obtained information. Our method considered the influence of the specific electrical conductivity of the base metals by forming a two-dimensional graduation characteristic of the thickness gauge by using several base metals with different specific electrical conductivity. The algorithm for point-in-polygon determination was applied, which allowed us to measure the thickness of the coatings and the specific electrical conductivity of the base metals as independent values. The equipment necessary to construct the two-dimensional graduation characteristic and the algorithm for calculation of the thickness are described in detail.

Zitieren

APA

Syasko, M., Solomenchuk, P., Soloviev, I., & Ampilova, N. (2023). A Technique for Multi-Parameter Signal Processing of an Eddy-Current Probe for Measuring the Thickness of Non-Conductive Coatings on Non-Magnetic Electrically Conductive Base Metals. Applied Sciences, 13(8), 5144. https://doi.org/10.3390/app13085144

Vancouver

Syasko M, Solomenchuk P, Soloviev I, Ampilova N. A Technique for Multi-Parameter Signal Processing of an Eddy-Current Probe for Measuring the Thickness of Non-Conductive Coatings on Non-Magnetic Electrically Conductive Base Metals. Applied Sciences. 2023;13(8):5144. doi:10.3390/app13085144

BibTeX
@article{Syasko2023,
  author = {Syasko, Michael and Solomenchuk, Pavel and Soloviev, Igor’ and Ampilova, Natalia},
  title = {A Technique for Multi-Parameter Signal Processing of an Eddy-Current Probe for Measuring the Thickness of Non-Conductive Coatings on Non-Magnetic Electrically Conductive Base Metals},
  journal = {Applied Sciences},
  year = {2023},
  volume = {13},
  number = {8},
  pages = {5144},
  doi = {10.3390/app13085144}
}
Kostenlos starten →