Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source

Shuaikun Yue, Zhong Ge, Jian Xu, Jianbin Xie, Zhiyong Xie, Songyuan Zhang, Jian Li

Applied Sciences · 16.02.2023 · 13 (4) · 2585

DOI: 10.3390/app13042585 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Sciences, online erschienen am 16.02.2023. Verfasst von Shuaikun Yue und 6 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Research Fund of Yunnan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The effects of different solar radiation intensities, heat flow density of indoor heat sources, outdoor wind speed, and the relative location of indoor heat sources on the natural ventilation performance of solar chimneys are investigated through three-dimensional numerical simulations. The mechanism of the mutual coupling of the solar chimney effect with the outdoor wind and indoor heat source heat plume is explored. The results of the study show that when the structural parameters of the solar chimney are the same, the heat flow density on the surface of the indoor heat source, the outdoor wind speed and the solar radiation intensity all have a gaining effect on the ventilation performance of the solar chimney and the effects of the three on the ventilation of the solar chimney promote each other, when the solar radiation intensity is 200 W/m2, the outdoor wind speed is 1.0 m/s, and the indoor heat source heat flow density increases from 0 to 1 500 W/m2, the solar chimney ventilation volume increases from 0.393 m3/s to 0.519 m3/s, the maximum value of the increase is 32.1%. In the other two cases, the maximum increase in solar chimney ventilation is 176.7% and 33.1%, respectively. Under the same conditions, solar chimney ventilation is optimal when the heat source is in the middle of the room. The presence of outdoor wind, however, affects the optimum design parameters of the solar chimney. Compared to the case where no outdoor wind is taken into account, the optimum inlet width of 0.2–0.3 m for the solar chimney no longer applies with outdoor wind, with the optimum value rising to 0.5 m.

Förderung

  • National Natural Science Foundation of China
  • Beijing Natural Science Foundation
  • Research Fund of Yunnan Province
  • Scientific Research Foundation of Kunming Metallurgy College

Zitieren

APA

Yue, S., Ge, Z., Xu, J., Xie, J., Xie, Z., Zhang, S., & Li, J. (2023). Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source. Applied Sciences, 13(4), 2585. https://doi.org/10.3390/app13042585

Vancouver

Yue S, Ge Z, Xu J, Xie J, Xie Z, Zhang S, et al. Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source. Applied Sciences. 2023;13(4):2585. doi:10.3390/app13042585

BibTeX
@article{Yue2023,
  author = {Yue, Shuaikun and Ge, Zhong and Xu, Jian and Xie, Jianbin and Xie, Zhiyong and Zhang, Songyuan and Li, Jian},
  title = {Analysis of the Ventilation Performance of a Solar Chimney Coupled to an Outdoor Wind and Indoor Heat Source},
  journal = {Applied Sciences},
  year = {2023},
  volume = {13},
  number = {4},
  pages = {2585},
  doi = {10.3390/app13042585}
}