EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Computer-Aided Diagnosis System for Sow Pregnancy Using Low-Frequency Portable Ultrasound Videos with Preprocessing and Augmentation Techniques

Yo Han Choi iD, Jae-Beom Park, Tae-Kyeong Kim iD, Hyeong-Sik Won, Hyun Ju Park iD, Hong-Jun Kim iD, Jo Eun Kim, Yong Dae Jeong iD, Jin-Soo Kim, Hyun-Sik Ham iD, Hyun-Chong Cho iD

Animals · 03.11.2026 · 16 (21) · 3470

DOI: 10.3390/ani16213470 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Animals, online erschienen am 03.11.2026. Verfasst von Yo Han Choi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Swine Science Division, National Institute of Animal Science, Rural Development Administration, Cheonan 31000, Republic of Korea. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Rural Development Administration, National Research Foundation of Korea, Korean government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate pregnancy diagnosis is important for reproductive management in pig farming. This study evaluated a computer-aided diagnosis workflow using portable low-frequency ultrasound videos from 1895 sows at two sites. Xception frame predictions were aggregated into video-level decisions. Original, Preprocessing (wavelet denoising and contrast-limited adaptive histogram equalization), Mixup, and their combination (Combined) were compared across ten repeated sow-level splits. Combined achieved mean accuracies of 84.5% and 85.3% in Datasets A and B, respectively, with pregnant-sow videos restricted to days 18–25 post-insemination. Compared with Original, mean specificity increased by 1.3 and 2.4 percentage points and Youden’s index by 1.7 and 2.3 points, while mean sensitivity was numerically similar. Paired 95% confidence intervals for specificity and Youden’s index differences excluded zero only in Dataset B, without adjustment for multiple comparisons. Paired comparisons of the area under the curve (AUC) did not establish improved discrimination. Mixup yielded the highest mean specificity and AUC, whereas Combined yielded higher mean sensitivity than Mixup. This trade-off varied across partition subsets. Cross-site and leave-one-session-out evaluations showed performance variability across acquisition settings, with no consistently best condition. These comparisons identify configuration-dependent trade-offs requiring further evaluation for diagnostic support.

Schlagwörter

Stichwörter der Autor:innen

computer-aided diagnosisdata augmentationdeep learningimage preprocessinglow-frequency portable ultrasound videosow pregnancy diagnosis

Autor:innen und Institutionen

  • Swine Science Division, National Institute of Animal Science, Rural Development Administration, Cheonan 31000, Republic of Korea.
  • Interdisciplinary Graduate Program for BIT Medical Convergence, Kangwon National University, Chuncheon 24341, Republic of Korea.
  • Department of Data Science, Kangwon National University, Chuncheon 24341, Republic of Korea.
  • College of Animal Life Sciences, Kangwon National University, Chuncheon 24341, Republic of Korea.
  • Department of Electronics Engineering, Kangwon National University, Chuncheon 24341, Republic of Korea.

ORCID-Profile: Yo Han Choi, Tae-Kyeong Kim, Hyun Ju Park, Hong-Jun Kim, Yong Dae Jeong, Hyun-Sik Ham, Hyun-Chong Cho

Förderung

  • Rural Development Administration
  • National Research Foundation of Korea
  • Korean government
  • Ministry of Agriculture, Food and Rural Affairs
  • Ministry of Science and ICT

Zitieren

APA

Choi, Y. H., Park, J. B., Kim, T. K., Won, H. S., Park, H. J., Kim, H. J., Kim, J. E., Jeong, Y. D., Kim, J. S., Ham, H. S., & Cho, H. C. (2026). Computer-Aided Diagnosis System for Sow Pregnancy Using Low-Frequency Portable Ultrasound Videos with Preprocessing and Augmentation Techniques. Animals, 16(21), 3470. https://doi.org/10.3390/ani16213470

Vancouver

Choi YH, Park JB, Kim TK, Won HS, Park HJ, Kim HJ, et al. Computer-Aided Diagnosis System for Sow Pregnancy Using Low-Frequency Portable Ultrasound Videos with Preprocessing and Augmentation Techniques. Animals. 2026;16(21):3470. doi:10.3390/ani16213470

BibTeX
@article{Choi2026,
  author = {Choi, Yo Han and Park, Jae-Beom and Kim, Tae-Kyeong and Won, Hyeong-Sik and Park, Hyun Ju and Kim, Hong-Jun and Kim, Jo Eun and Jeong, Yong Dae and Kim, Jin-Soo and Ham, Hyun-Sik and Cho, Hyun-Chong},
  title = {Computer-Aided Diagnosis System for Sow Pregnancy Using Low-Frequency Portable Ultrasound Videos with Preprocessing and Augmentation Techniques},
  journal = {Animals},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3470},
  doi = {10.3390/ani16213470}
}
Kostenlos starten →