EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Two-House Field Comparison of Multi-Parameter and Conventional Environmental Control for Rabbits Under Hot–Humid Summer Conditions

Quan-Gang Wang iD, Qian Jing, Guoxin Wu, Hang Shu iD, Zhong-Ying Liu, Ronghua Ji iD, Yao Guo, Zhong-Hong Wu

Animals · 01.11.2026 · 16 (21) · 3450

DOI: 10.3390/ani16213450 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Animals, online erschienen am 01.11.2026. Verfasst von Quan-Gang Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Animal Nutrition and Feeding, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Agriculture Research System.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study compared a programmable logic controller (PLC) combining indoor temperature, outdoor temperature, and outdoor relative humidity with conventional temperature-triggered pad cooling and manual fan adjustment in two commercial rabbit houses in Leshan, China, a region characterized by a hot and humid climate. The 33-day summer trial included 108 selected Hyla rabbits aged 39 d per house. The PLC house had a mean air temperature 0.36 °C higher and relative humidity 4.34 percentage points lower than the control house. Final body weight and average daily gain were higher, while feed conversion did not differ significantly. Intra-abdominal temperature near the cooling pads was 0.29 °C lower. Estimated cooling pad recirculation was 81.0% lower and combined fan and pump electricity use was 21.2% higher. A partial-budget analysis at a standardized scale of 3000 retained rabbit production-equivalents estimated a benefit 2955.95 Chinese yuan (CNY) higher for the treatment house than for the control house under the specified prices and scaling assumptions. Each strategy was applied in one house, so these preliminary differences cannot be separated from house effects. These observations support further evaluation in independently replicated houses, with animal responses, resource use, and deployment costs assessed together.

Schlagwörter

Stichwörter der Autor:innen

cooling pad recirculationeconomic analysiselectricity useevaporative coolinghot–humid climatemulti-parameter control strategyphysiological and growth performancerabbit housing

Autor:innen und Institutionen

  • State Key Laboratory of Animal Nutrition and Feeding, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China.
  • College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China.

ORCID-Profile: Quan-Gang Wang, Hang Shu, Ronghua Ji

Förderung

  • China Agriculture Research System

Zitieren

APA

Wang, Q. G., Jing, Q., Wu, G., Shu, H., Liu, Z. Y., Ji, R., Guo, Y., & Wu, Z. H. (2026). A Two-House Field Comparison of Multi-Parameter and Conventional Environmental Control for Rabbits Under Hot–Humid Summer Conditions. Animals, 16(21), 3450. https://doi.org/10.3390/ani16213450

Vancouver

Wang QG, Jing Q, Wu G, Shu H, Liu ZY, Ji R, et al. A Two-House Field Comparison of Multi-Parameter and Conventional Environmental Control for Rabbits Under Hot–Humid Summer Conditions. Animals. 2026;16(21):3450. doi:10.3390/ani16213450

BibTeX
@article{Wang2026,
  author = {Wang, Quan-Gang and Jing, Qian and Wu, Guoxin and Shu, Hang and Liu, Zhong-Ying and Ji, Ronghua and Guo, Yao and Wu, Zhong-Hong},
  title = {A Two-House Field Comparison of Multi-Parameter and Conventional Environmental Control for Rabbits Under Hot–Humid Summer Conditions},
  journal = {Animals},
  year = {2026},
  volume = {16},
  number = {21},
  pages = {3450},
  doi = {10.3390/ani16213450}
}