Abstract (Originalsprache)

Background

Continuous ECG and arterial pressure monitoring provide beat-level information, but composite interpretation remains largely dependent on separate measurements.

Objective

To describe an investigational physiological architecture that integrates electrical instability, pump/forward-flow behavior and vascular tone/load into interpretable time-varying patterns. Framework: The Electrical Instability Score (EIS) summarizes rate, rhythm and conduction changes; the Myocardial/Pump Performance Score (MPS) combines load-dependent arterial-waveform features and a timing variable labeled PEP, which in this peripheral configuration represents pulse arrival time rather than true pre-ejection period; and the Vascular Tone/Load Score (VTS) considers diastolic pressure, pressure decay and arterial morphology. Cross-domain interpretation separates phenotype, trajectory, clinical hemodynamic state and measurement confidence. Because pressure and flow are jointly determined by cardiac energy delivery and arterial impedance, neither calculated systemic vascular resistance nor an isolated pressure-waveform measure should be equated with ventricular afterload or intrinsic contractility.

Implications

Prespecified combinations of these domains may identify pump-dominant, low-tone, preload-limited, mixed and electrical-dominant patterns suitable for independent clinical adjudication. The proposed scores, weights and classification rules have not been clinically validated; their incremental utility, reliability and clinical impact require prospective evaluation.

Zitieren

APA

Rola, P., & Bhardwaj, V. (2026). Beyond Threshold Alarms: Continuous Electrical, Pump and Vascular Phenotyping from Bedside Waveforms. Anesthesia Research, 3(4), 37. https://doi.org/10.3390/anesthres3040037

Vancouver

Rola P, Bhardwaj V. Beyond Threshold Alarms: Continuous Electrical, Pump and Vascular Phenotyping from Bedside Waveforms. Anesthesia Research. 2026;3(4):37. doi:10.3390/anesthres3040037

BibTeX
@article{Rola2026,
  author = {Rola, Philippe and Bhardwaj, Vimal},
  title = {Beyond Threshold Alarms: Continuous Electrical, Pump and Vascular Phenotyping from Bedside Waveforms},
  journal = {Anesthesia Research},
  year = {2026},
  volume = {3},
  number = {4},
  pages = {37},
  doi = {10.3390/anesthres3040037}
}
Kostenlos starten →