Quantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics
Analytica · 08.05.2024 · 5 (2) · 219-232
DOI: 10.3390/analytica5020014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica, online erschienen am 08.05.2024. Verfasst von Alessandro Zappi und 6 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Excellence program.
Abstract (Originalsprache)
A novel approach for the quantification of recycled polyethylene terephthalate (r-PET) in commercial bottles is presented. Fifty-eight bottle samples from several brands and producers containing different percentages of r-PET were purchased from the market. Samples were analyzed by two spectroscopic methods: near-infrared (NIR) spectroscopy and attenuated total reflection (ATR) spectroscopy in the mid-infrared (MIR) region. No chemical pre-treatment was applied before analyses. The spectra were analyzed by partial-least squares (PLS) regression, and two models for NIR and MIR data were computed. Then, a multi-block regression was applied to join the two datasets. All models were validated by cross-validation and by excluding and projecting onto the model the replicated spectra of one sample at a time. Results demonstrated the potential of this approach, especially considering the variability of commercial samples in terms of additives, shape, or thickness of the bottles: for samples close to the centroids of the models (i.e., from 10 to 50% r-PET), the predictions of multi-block method seldom departed from the expected values of ±10%. Only for samples with 0% declared r-PET, the models showed poor prediction abilities.
Förderung
- Department of Excellence program
Zitieren
APA
Zappi, A., Biancolillo, A., Kassouf, N., Marassi, V., Morozzi, P., Tositti, L., & Melucci, D. (2024). Quantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics. Analytica, 5(2), 219-232. https://doi.org/10.3390/analytica5020014
Vancouver
Zappi A, Biancolillo A, Kassouf N, Marassi V, Morozzi P, Tositti L, et al. Quantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics. Analytica. 2024;5(2):219-232. doi:10.3390/analytica5020014
BibTeX
@article{Zappi2024,
author = {Zappi, Alessandro and Biancolillo, Alessandra and Kassouf, Nicholas and Marassi, Valentina and Morozzi, Pietro and Tositti, Laura and Melucci, Dora},
title = {Quantification of Recycled PET in Commercial Bottles by IR Spectroscopy and Chemometrics},
journal = {Analytica},
year = {2024},
volume = {5},
number = {2},
pages = {219--232},
doi = {10.3390/analytica5020014}
}
EUVIMED