Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis

Edwin Villagran, Jorge Flores-Velasquez, Cruz Ernesto Aguilar Rodríguez, Rodrigo Gil, Carlos Ricardo Bojacá

Agronomy · 19.11.2026 · 16 (22) · 2339

DOI: 10.3390/agronomy16222339 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Agronomy, online erschienen am 19.11.2026. Verfasst von Edwin Villagran und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Greenhouse design in tropical highlands must reconcile passive heat removal with the microclimatic requirements of horticultural crops. This study assessed how gutter height and roof opening area interact with external wind to influence ventilation, temperature, humidity, and atmospheric evaporative demand in a five-span greenhouse in the Bogotá Savanna, Colombia. A two-dimensional, steady-state computational fluid dynamics (CFD) model was used to simulate 60 combinations of gutter height (2–6 m), roof opening ratio (10–30% of floor area), and wind velocity (0–1.7 m s−1), considering roof-only ventilation and an uncropped interior. Response surface methodology (RSM) characterized the combined effects of the three factors. Area-normalized ventilation ranged from 0.026 to 0.163 m3 s−1 m−2, while mean air temperature ranged from 26.2 to 42.8 °C. Under windless conditions and a 30% opening ratio, increasing gutter height from 2 to 6 m reduced mean temperature from 35.3 to 28.9 °C. Across the warmest and coolest scenarios, estimated vapor pressure deficit decreased from 6.49 to 1.37 kPa. However, these scenarios shared a mean growing-zone air velocity of 0.3 m s−1, showing that greater air exchange did not necessarily increase local air movement. The quadratic models achieved adjusted R2 = 0.900–0.986; withholding complete height–opening combinations yielded RMSE values of 0.00596 m3 s−1 m−2 for ventilation, 0.895 °C for temperature, and 3.29 percentage points for relative humidity. Despite improved cooling, the lowest mean temperature exceeded the cited daytime ranges for rose, carnation, chrysanthemum, and alstroemeria. The findings identify greenhouse height and roof opening area as complementary design variables, while demonstrating that ventilation gains alone do not establish crop-specific climatic suitability under the evaluated conditions.

Zitieren

APA

Villagran, E., Flores-Velasquez, J., Rodríguez, C. E. A., Gil, R., & Bojacá, C. R. (2026). Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis. Agronomy, 16(22), 2339. https://doi.org/10.3390/agronomy16222339

Vancouver

Villagran E, Flores-Velasquez J, Rodríguez CEA, Gil R, Bojacá CR. Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis. Agronomy. 2026;16(22):2339. doi:10.3390/agronomy16222339

BibTeX
@article{Villagran2026,
  author = {Villagran, Edwin and Flores-Velasquez, Jorge and Rodríguez, Cruz Ernesto Aguilar and Gil, Rodrigo and Bojacá, Carlos Ricardo},
  title = {Coupled Effects of Gutter Height and Roof Opening Ratio on Greenhouse Microclimate: CFD Modeling and Response Surface Analysis},
  journal = {Agronomy},
  year = {2026},
  volume = {16},
  number = {22},
  pages = {2339},
  doi = {10.3390/agronomy16222339}
}