EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Mitigating Summer Heat Stress and Reducing Energy Demand in Greenhouses Through Earth-to-Air Heat Exchanger (EAHE) Systems

Rodrigues Pascoal Castro, Luís Carlos Carvalho Pires, Pedro Dinho da Silva

AgriEngineering · 27.07.2026 · 8 (8) · 308

DOI: 10.3390/agriengineering8080308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AgriEngineering, online erschienen am 27.07.2026. Verfasst von Rodrigues Pascoal Castro und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In Mediterranean countries such as Portugal, summer heatwaves increasingly threaten agricultural productivity by disrupting crop physiological processes. Greenhouse cultivation often exacerbates heat stress, while conventional cooling systems such as air conditioning and evaporative cooling impose unsustainable energy demands. This study investigates an Earth-to-Air Heat Exchanger (EAHE) system consisting of a five-tier helical PVC pipe configuration (29 m, buried at a depth of 3 m), installed in a prototype polycarbonate greenhouse in Covilhã, Portugal, and monitored under real summer conditions. Four ventilation scenarios were simulated in EnergyPlus 25.1, and a segmented NTU thermal model, implemented as a Python plugin via the pyenergyplus API, predicted the EAHE outlet temperature with CV(RMSE) values of 1.47% at 30 m3/h and 3.0% at 50 m3/h. The IPMA meteorological dataset provided the best simulation accuracy (RMSE = 2.31 °C, R2 = 0.978). In simulations based on the experimentally calibrated models, EAHE preconditioning reduced accumulated heat stress degree-hours above 28 °C by 9.1 to 9.5% and lowered peak indoor temperature by up to 2.60 °C, at system COPs of 6.9 to 10.6, which are 2.3 to 3.5 times higher than conventional vapour-compression cooling; propagated measurement uncertainties confirm the robustness of this COP advantage. A model-based parametric scale analysis indicated that geometrically scaled circuits (DN200, DN400) achieve degree-hour reductions of 67 and 91%, supporting EAHE scalability through geometric proportioning, pending experimental validation at larger scales.

Förderung

  • Fundação para a Ciência e Tecnologia

Zitieren

APA

Castro, R. P., Pires, L. C. C., & Silva, P. D. D. (2026). Mitigating Summer Heat Stress and Reducing Energy Demand in Greenhouses Through Earth-to-Air Heat Exchanger (EAHE) Systems. AgriEngineering, 8(8), 308. https://doi.org/10.3390/agriengineering8080308

Vancouver

Castro RP, Pires LCC, Silva PDD. Mitigating Summer Heat Stress and Reducing Energy Demand in Greenhouses Through Earth-to-Air Heat Exchanger (EAHE) Systems. AgriEngineering. 2026;8(8):308. doi:10.3390/agriengineering8080308

BibTeX
@article{Castro2026,
  author = {Castro, Rodrigues Pascoal and Pires, Luís Carlos Carvalho and Silva, Pedro Dinho da},
  title = {Mitigating Summer Heat Stress and Reducing Energy Demand in Greenhouses Through Earth-to-Air Heat Exchanger (EAHE) Systems},
  journal = {AgriEngineering},
  year = {2026},
  volume = {8},
  number = {8},
  pages = {308},
  doi = {10.3390/agriengineering8080308}
}
Kostenlos starten →