EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Finite Element Thermo-Structural Analysis of a Structurally Integrated Multilayer Composite Cryogenic Thermal Barrier for Liquid Hydrogen Tank Applications

Alexa-Andreea Crisan, Mircea Moraru, Daniel-Eugeniu Crunteanu, Alina Bogoi

Aerospace · 18.05.2026 · 13 (5) · 475

DOI: 10.3390/aerospace13050475 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aerospace, online erschienen am 18.05.2026. Verfasst von Alexa-Andreea Crisan und 3 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: COMOTI-Romanian Research & Development Institute for Gas Turbines.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effective thermal insulation of cryogenic liquid hydrogen (LH2) storage tanks remains a critical engineering challenge, as conventional vacuum-based or monolithic systems are constrained by manufacturing complexity, mechanical vulnerability, and poor geometric adaptability. This study presents the design and numerical verification of a four-layer octagonal composite thermal shield fabricated via additive manufacturing: an AA5083 structural layer (5 mm), a boron nitride-doped ceramic plate (1 mm), up to 290 stacked graphene sheets in a sealed compartment, and an outer Fe3S4-TiO2 nanocomposite layer (~30 µm). Steady-state and transient FEA in ANSYS evaluated three convective boundary conditions (h = 10, 15, and 20 W/m2·K), with the inner wall fixed at 20 K. Temperature distributions remained essentially invariant across all cases (20 K inner, ~20.12 K outer), confirming that thermal performance is governed by the multilayer architecture rather than convective intensity. The shield achieved a mean heat flux of 1684 W/m2, R_total ≈ 0.163 m2K/W, and a boil-off rate of 13.9 g/hour. Comparative FEA against NASA US9617069 (q = 193.35 W/m2) and JP2018-119634A (q = 37.975 W/m2) highlights the compactness advantage of the proposed 6 mm shield; the coupled thermo-structural assessment yielded a safety factor of 64,182, confirming elastic-regime operation at 20 K.

Förderung

  • COMOTI-Romanian Research & Development Institute for Gas Turbines

Zitieren

APA

Crisan, A., Moraru, M., Crunteanu, D., & Bogoi, A. (2026). Design and Finite Element Thermo-Structural Analysis of a Structurally Integrated Multilayer Composite Cryogenic Thermal Barrier for Liquid Hydrogen Tank Applications. Aerospace, 13(5), 475. https://doi.org/10.3390/aerospace13050475

Vancouver

Crisan A, Moraru M, Crunteanu D, Bogoi A. Design and Finite Element Thermo-Structural Analysis of a Structurally Integrated Multilayer Composite Cryogenic Thermal Barrier for Liquid Hydrogen Tank Applications. Aerospace. 2026;13(5):475. doi:10.3390/aerospace13050475

BibTeX
@article{Crisan2026,
  author = {Crisan, Alexa-Andreea and Moraru, Mircea and Crunteanu, Daniel-Eugeniu and Bogoi, Alina},
  title = {Design and Finite Element Thermo-Structural Analysis of a Structurally Integrated Multilayer Composite Cryogenic Thermal Barrier for Liquid Hydrogen Tank Applications},
  journal = {Aerospace},
  year = {2026},
  volume = {13},
  number = {5},
  pages = {475},
  doi = {10.3390/aerospace13050475}
}
Kostenlos starten →