Robust Backstepping Control of Parallel-Connected Inverters Supplying an Induction Motor Under Inverter Fault Conditions
Actuators · 23.10.2026 · 15 (11) · 558
DOI: 10.3390/act15110558 ↗Kurz gefasst
Fachartikel in der Zeitschrift Actuators, online erschienen am 23.10.2026. Verfasst von Zaidi Elyazid und 6 weiteren Autor:innen. Die Arbeit nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Clean Energy Transition Partnership, UEFISCDI.
Abstract (Originalsprache)
This paper proposes a fault-robust backstepping-based control strategy for induction motor (IM) drives fed by parallel-connected voltage-source inverters (VSIs). The developed control scheme is engineered to achieve precise speed tracking, optimal current sharing among parallel inverter legs, and effective suppression of zero-sequence circulating currents (ZSCCs) under both normal operation and inverter fault scenarios. Initially, a comprehensive mathematical model of the parallel inverter-fed IM drive is formulated in the synchronous reference frame, rigorously incorporating the inter-inverter coupling dynamics. Utilizing Lyapunov stability theory, a nonlinear backstepping controller is subsequently synthesized to guarantee closed-loop stability and the asymptotic convergence of tracking errors. To evaluate the robustness and fault-tolerance of the proposed method, open-circuit faults in the inverter power switches are investigated. The dynamic impacts of these faults on motor speed, electromagnetic torque, stator currents, current distribution, and ZSCCs are thoroughly analyzed through both simulation and experimental validations. The experimental findings indicate that the proposed controller successfully sustains stable speed regulation, enhances current sharing, and significantly mitigates circulating currents and torque ripples during fault conditions. Furthermore, comparative evaluations against conventional proportional–integral controllers highlight the superior transient response and enhanced fault resilience of the suggested approach. Ultimately, these results substantiate the efficacy of the proposed backstepping-based control framework in ensuring highly reliable operation of parallel inverter-fed IM drives across diverse operating states.
Förderung
- Clean Energy Transition Partnership
- UEFISCDI
Zitieren
APA
Elyazid, Z., Benbouhenni, H., Mabrek, A., Marouani, K., Mazare, A. G., Ionescu, L. M., & Bizon, N. (2026). Robust Backstepping Control of Parallel-Connected Inverters Supplying an Induction Motor Under Inverter Fault Conditions. Actuators, 15(11), 558. https://doi.org/10.3390/act15110558
Vancouver
Elyazid Z, Benbouhenni H, Mabrek A, Marouani K, Mazare AG, Ionescu LM, et al. Robust Backstepping Control of Parallel-Connected Inverters Supplying an Induction Motor Under Inverter Fault Conditions. Actuators. 2026;15(11):558. doi:10.3390/act15110558
BibTeX
@article{Elyazid2026,
author = {Elyazid, Zaidi and Benbouhenni, Habib and Mabrek, Abdelhakim and Marouani, Khoudir and Mazare, Alin Gheorghita and Ionescu, Laurentiu Mihai and Bizon, Nicu},
title = {Robust Backstepping Control of Parallel-Connected Inverters Supplying an Induction Motor Under Inverter Fault Conditions},
journal = {Actuators},
year = {2026},
volume = {15},
number = {11},
pages = {558},
doi = {10.3390/act15110558}
}
EUVIMED