EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Parameter Identification of a Lower-Limb Exoskeleton Using RLS–AGWO

Wentao Sheng, Yunxia Cao, Li Ding, Tianyu Gao

Actuators · 17.08.2026 · 15 (8) · 447

DOI: 10.3390/act15080447 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Actuators, online erschienen am 17.08.2026. Verfasst von Wentao Sheng und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Jiangsu Province, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate dynamic parameters are required for model-based control of lower-limb exoskeletons, but limited excitation, transmission friction, and assembly-dependent uncertainty can degrade conventional estimates. This study examines a two-stage method that combines recursive least squares (RLS) with an adaptive grey wolf optimizer (AGWO). Offline RLS tracks the base-parameter trajectory and expands its post-convergence extrema to construct a finite search space; a non-smooth friction severity index then modulates the GWO convergence schedule. The method was evaluated on a pedestal-mounted, single-degree-of-freedom hip mechanism using a 5 s calibration trajectory and a separate 7 s validation trajectory. Deterministic least squares (LS) and bound-constrained least squares (BCLS) were compared with standard PSO, RLS–PSO, RLS–GA, RLS–GWO, and RLS–AGWO. Each stochastic method used a population of 30, with 80 iterations (2400 fitness evaluations) and 30 independent seeds. On the independent trajectory, BCLS obtained an RMSE of 0.1152 Nm. Median validation RMSEs were 0.1152, 0.1152, 0.1562, and 0.1516 Nm for RLS–PSO, RLS–GA, RLS–GWO, and RLS–AGWO, respectively. Thus, the adaptive schedule improved median GWO error by 3.0%, but deterministic BCLS was both more accurate and faster for the present linear-in-parameters model. AGWO is therefore not mathematically necessary for the current convex objective; its potential advantage should be tested with genuinely nonlinear friction parameterizations. The conclusions remain limited to a single-axis pedestal experiment and do not establish performance during human-worn gait.

Förderung

  • Natural Science Foundation of Jiangsu Province
  • National Natural Science Foundation of China

Zitieren

APA

Sheng, W., Cao, Y., Ding, L., & Gao, T. (2026). Dynamic Parameter Identification of a Lower-Limb Exoskeleton Using RLS–AGWO. Actuators, 15(8), 447. https://doi.org/10.3390/act15080447

Vancouver

Sheng W, Cao Y, Ding L, Gao T. Dynamic Parameter Identification of a Lower-Limb Exoskeleton Using RLS–AGWO. Actuators. 2026;15(8):447. doi:10.3390/act15080447

BibTeX
@article{Sheng2026,
  author = {Sheng, Wentao and Cao, Yunxia and Ding, Li and Gao, Tianyu},
  title = {Dynamic Parameter Identification of a Lower-Limb Exoskeleton Using RLS–AGWO},
  journal = {Actuators},
  year = {2026},
  volume = {15},
  number = {8},
  pages = {447},
  doi = {10.3390/act15080447}
}
Kostenlos starten →