Kurz gefasst

Fachartikel in der Zeitschrift Actuators, online erschienen am 11.06.2026. Verfasst von Jianwei Cui und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Foundation of Jiangsu Provincial Health Commission, China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The contact force between the ultrasound probe and human skin directly affects image quality, patient safety, and comfort. In infant developmental dysplasia of the hip (DDH) ultrasound examinations, higher force control precision is required, as infants have thin skin and soft cartilage that are easily deformed under excessive probe pressure. This paper proposes a comprehensive force control method for DDH ultrasound robots. Firstly, an online gravity calibration approach is employed to estimate the installation tilt, sensor zero offset, and probe center of gravity, thereby improving force measurement accuracy. Then, a torque-based pose control algorithm is adopted to achieve conformal probe–skin contact. Finally, a variable admittance control strategy based on fuzzy neural network (FNN) is proposed, which adaptively regulates the damping coefficient based on the force error and its rate, enabling stable force control without explicit soft-tissue modeling. Experiments on an infant phantom and human skin show that the proposed method achieves force fluctuation amplitudes of 0.0984 ± 0.0012 N and 0.0976 ± 0.0014 N, respectively, with absolute steady-state force errors below 0.01 N. Compared with conventional admittance control, it significantly reduces force oscillations and improves tracking accuracy. In infant experiments, the method enables smooth convergence to the desired force and maintains relatively stable probe–skin interaction, which contributes to consistent ultrasound image acquisition and reduces tissue deformation. These results suggest that the proposed method can provide a feasible force control basis for stable and gentle robotic DDH ultrasound scanning.

Förderung

  • Research Foundation of Jiangsu Provincial Health Commission, China

Zitieren

APA

Cui, J., Zhang, X., Dai, Y., & Zhang, W. (2026). Research on Robotic Force Control for Infant Hip Ultrasound. Actuators, 15(6), 333. https://doi.org/10.3390/act15060333

Vancouver

Cui J, Zhang X, Dai Y, Zhang W. Research on Robotic Force Control for Infant Hip Ultrasound. Actuators. 2026;15(6):333. doi:10.3390/act15060333

BibTeX
@article{Cui2026,
  author = {Cui, Jianwei and Zhang, Xinyu and Dai, Yuxiang and Zhang, Wenyi},
  title = {Research on Robotic Force Control for Infant Hip Ultrasound},
  journal = {Actuators},
  year = {2026},
  volume = {15},
  number = {6},
  pages = {333},
  doi = {10.3390/act15060333}
}
Kostenlos starten →