Coaxially Printed Electroablation Catheter for Magnetically Actuated Navigation and Localized Tissue Ablation
Actuators · 26.05.2026 · 15 (6) · 289
DOI: 10.3390/act15060289 ↗Kurz gefasst
Fachartikel in der Zeitschrift Actuators, online erschienen am 26.05.2026. Verfasst von Xiaonan Sun und 6 weiteren Autor:innen. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Guangdong Basic and Applied Basic Research Foundation.
Abstract (Originalsprache)
Magnetically actuated catheters have attracted increasing attention for minimally invasive interventions because they enable remote, non-contact steering in confined and tortuous anatomical environments. However, integrating magnetic actuation, electroablation capability, and high structural compliance into a single soft catheter remains challenging. Here, we present a coaxially printed magnetically actuated electroablation catheter (MEC). The MEC is fabricated via a coaxial 3D printing process, combining a highly flexible PDMS outer sheath with a continuously deformable eutectic gallium–indium (eGaIn) conductive core, followed by the distal assembly of a magnetic ring and a copper electrode. This structural design preserves intrinsic mechanical flexibility while maintaining stable electrical conductivity under bending deformation. To achieve active catheter steering, an eight-axis electromagnetic actuation system was developed to generate controllable magnetic fields for tip deflection and guidance. The MEC exhibited effective navigation and manipulation in maze traversal and selective navigation within a 3D-printed vascular model. Furthermore, ex vivo porcine liver and in vivo rat liver electroablation experiments verified that the MEC could be magnetically navigated to designated sites for localized electroablation. This work provides a new strategy for precise, minimally invasive ablation of target tissues in confined and difficult-to-access anatomical environments.
Förderung
- National Natural Science Foundation of China
- Guangdong Basic and Applied Basic Research Foundation
Zitieren
APA
Sun, X., Wu, T., Chen, F., Yu, Q., Zhang, B., Jiang, L., & Zhang, Y. (2026). Coaxially Printed Electroablation Catheter for Magnetically Actuated Navigation and Localized Tissue Ablation. Actuators, 15(6), 289. https://doi.org/10.3390/act15060289
Vancouver
Sun X, Wu T, Chen F, Yu Q, Zhang B, Jiang L, et al. Coaxially Printed Electroablation Catheter for Magnetically Actuated Navigation and Localized Tissue Ablation. Actuators. 2026;15(6):289. doi:10.3390/act15060289
BibTeX
@article{Sun2026,
author = {Sun, Xiaonan and Wu, Tong and Chen, Fuqian and Yu, Qingyu and Zhang, Binbin and Jiang, Lelun and Zhang, Yuanxi},
title = {Coaxially Printed Electroablation Catheter for Magnetically Actuated Navigation and Localized Tissue Ablation},
journal = {Actuators},
year = {2026},
volume = {15},
number = {6},
pages = {289},
doi = {10.3390/act15060289}
}
EUVIMED