A DACO-XGBoost-Driven Method for Evaluating Braking Performance of High-Speed Elevators
Actuators · 16.04.2026 · 15 (4) · 224
DOI: 10.3390/act15040224 ↗Kurz gefasst
Fachartikel in der Zeitschrift Actuators, online erschienen am 16.04.2026. Verfasst von Yefeng Jiang und 6 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Planning Project of Jiaxing, Zhejiang Provincial Natural Science Foundation of China, Science and Technology Program Project of Zhejiang Provincial Market Supervision Administration.
Abstract (Originalsprache)
To address the high labor intensity of weight handling and the low accuracy of testing outcomes in the 125% rated-load down-running braking test for high-speed elevators, this study proposes a numerical-model-driven evaluation method for elevator braking capability based on Dynamic Ant Colony Optimization–eXtreme Gradient Boosting (DACO-XGBoost). Firstly, to overcome the limited prediction accuracy caused by insufficient measured samples during braking analysis, vibration and noise effects are both considered, and thus an equivalent dynamic analysis is conducted for no-load up-running and 125% load down-running conditions. Based on this, a simulation-data generation approach was developed to produce loaded down-running braking samples from the no-load up-running operating condition. Secondly, by combining the simulated samples generated by the above model with a limited set of measured samples, an XGBoost model optimized by a dynamic ant colony algorithm was constructed, improving the model’s ability to fit the complex nonlinear relationships in the elevator braking process. This mitigates the constraints imposed by sample scarcity and enables accurate prediction of key braking-performance parameters. Experimental results demonstrate that the proposed DACO-XGBoost substantially improves prediction accuracy. For braking distance, it decreased from 7.5453 to 0.5661 (RMSE) and from 2.7452 to 0.0370 (MAE). For slip amount, it decreased from 60.0307 to 1.2200 (RMSE) and from 7.7401 to 0.8146 (MAE), respectively. Furthermore, after comparisons with RF, GA-RF, and PSO-RF, the effectiveness of the proposed method for quantitative evaluation of braking performance in high-speed elevators was verified.
Förderung
- Science and Technology Planning Project of Jiaxing
- Zhejiang Provincial Natural Science Foundation of China
- Science and Technology Program Project of Zhejiang Provincial Market Supervision Administration
Zitieren
APA
Jiang, Y., Li, D., Su, W., Yi, C., Li, K., Shen, W., & Xu, S. (2026). A DACO-XGBoost-Driven Method for Evaluating Braking Performance of High-Speed Elevators. Actuators, 15(4), 224. https://doi.org/10.3390/act15040224
Vancouver
Jiang Y, Li D, Su W, Yi C, Li K, Shen W, et al. A DACO-XGBoost-Driven Method for Evaluating Braking Performance of High-Speed Elevators. Actuators. 2026;15(4):224. doi:10.3390/act15040224
BibTeX
@article{Jiang2026,
author = {Jiang, Yefeng and Li, Dongxin and Su, Wanbin and Yi, Cancan and Li, Ke and Shen, Wei and Xu, Shulong},
title = {A DACO-XGBoost-Driven Method for Evaluating Braking Performance of High-Speed Elevators},
journal = {Actuators},