Research on the Flow and Heat Transfer Characteristics of a Molten Salt Globe Valve Based on an Electromagnetic Induction Heating System
Actuators · 13.01.2026 · 15 (1) · 50
DOI: 10.3390/act15010050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Actuators, online erschienen am 13.01.2026. Verfasst von Shuxun Li und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Program Funding of Gansu Province, The Double First-Class Key Program of Gansu Provincial Department of Education.
Abstract (Originalsprache)
To promote the transition to a cleaner energy structure and support the achievement of the “carbon peak and carbon neutrality” goals, concentrated solar power (CSP) technology has attracted increasing attention. The molten salt globe valve, as a key control component in CSP systems, faces significant challenges related to low-temperature salt crystallization and thermal stress control. This study proposes an active electromagnetic induction heating method based on a triangular double-helix cross-section coil to address issues such as molten salt blockage in the seal bellows and excessive thermal stress during heating. First, electromagnetic simulation comparisons show that the ohmic loss of the proposed coil is approximately 3.5 times and 1.8 times higher than that of conventional circular and rectangular coils, respectively, demonstrating superior heating uniformity and energy efficiency. Second, transient electromagnetic-thermal-fluid-structure multiphysics coupling analysis reveals that during heating, the temperature in the bellows seal region stabilizes above 543.15 K, exceeding the solidification point of the molten salt, while the whole valve reaches thermal stability within about 1000 s, effectively preventing local solidification. Finally, thermal stress analysis indicates that under a preheating condition of 473.15 K, the transient thermal shock stress on the valve body and bellows is reduced by 266.84% and 253.91%, respectively, compared with the non-preheating case, with peak stresses remaining below the allowable stress limit of the material, thereby significantly extending the service life of the valve. This research provides an effective solution for ensuring reliable operation of molten salt valves and improving the overall performance of CSP systems.
Förderung
- Science and Technology Program Funding of Gansu Province
- The Double First-Class Key Program of Gansu Provincial Department of Education
Zitieren
APA
Li, S., Wen, X., Zhang, B., Yang, L., Tian, Y., & Meng, X. (2026). Research on the Flow and Heat Transfer Characteristics of a Molten Salt Globe Valve Based on an Electromagnetic Induction Heating System. Actuators, 15(1), 50. https://doi.org/10.3390/act15010050
Vancouver
Li S, Wen X, Zhang B, Yang L, Tian Y, Meng X. Research on the Flow and Heat Transfer Characteristics of a Molten Salt Globe Valve Based on an Electromagnetic Induction Heating System. Actuators. 2026;15(1):50. doi:10.3390/act15010050
BibTeX
@article{Li2026,
author = {Li, Shuxun and Wen, Xiaoya and Zhang, Bohao and Yang, Lingxia and Tian, Yuhao and Meng, Xiaoqi},
title = {Research on the Flow and Heat Transfer Characteristics of a Molten Salt Globe Valve Based on an Electromagnetic Induction Heating System},
journal = {Actuators},
year = {2026},
volume = {15},
number = {1},
pages = {50},
doi = {10.3390/act15010050}
}