Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order Controller
Algorithms · 22.11.2026 · 19 (12) · 1020
DOI: 10.3390/a19121020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Algorithms, online erschienen am 22.11.2026. Verfasst von Gauri Shankar und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EU Clean Energy Transition Partnership, Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare.
Abstract (Originalsprache)
Effective load frequency control is essential for maintaining frequency stability and reliable operation of interconnected power systems, particularly in the presence of load disturbances and system nonlinearities. Therefore, the present work proposes a new hybrid fuzzy tilt integral with tilt integral derivative-based fractional-order controller for the load frequency control loop of a four-area interlinked power system comprising thermal and hydro-generating units. Additionally, the suggested controller is optimally designed with its gains and associated input fuzzy scaling factors fine-tuned using salp swarm optimization algorithm to improve the frequency dynamics of the system. The efficacy of the optimized proposed controller in terms of transient performance and integral performance indices is examined with respect to the other studied hybrid proportional integral with tilt derivative and tilt integral with tilt integral derivative fractional-order controllers following load disturbance, considering linear operating conditions and nonlinearities such as generation rate constraints and governor-dead band. The simulation results reveal that the proposed controller offers faster damping of frequency and tie-line power and reduced performance indices over the other counterparts. Besides, a sensitivity analysis is also carried out that reveals that satisfactory frequency regulation is maintained under selected variations in system parameters and loading conditions without retuning the controller. The results obtained highlight the potential of the proposed hybrid fuzzy fractional-order control strategy for improving the dynamic performance of interconnected power systems under the considered operating scenarios.
Förderung
- EU Clean Energy Transition Partnership
- Unitatea Executiva Pentru Finantarea Invatamantului Superior Si A Cercetarii Stiintifice Universitare
Zitieren
APA
Shankar, G., Kumari, S., Bhowmik, S., Biswal, S. R., Jha, A. V., Bizon, N., & Tulbure, A. (2026). Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order Controller. Algorithms, 19(12), 1020. https://doi.org/10.3390/a19121020
Vancouver
Shankar G, Kumari S, Bhowmik S, Biswal SR, Jha AV, Bizon N, et al. Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order Controller. Algorithms. 2026;19(12):1020. doi:10.3390/a19121020
BibTeX
@article{Shankar2026,
author = {Shankar, Gauri and Kumari, Sandhya and Bhowmik, Satadal and Biswal, Saubhagya Ranjan and Jha, Amitkumar V. and Bizon, Nicu and Tulbure, Adrian},
title = {Load Frequency Control of Multi-Area Power System Using Hybrid Fuzzy Tilt Integral with Tilt Integral Derivative-Based Fractional Order Controller},
journal = {Algorithms},
year = {2026},
volume = {19},
number = {12},
pages = {1020},
doi = {10.3390/a19121020}
}