An Improved Sinh Cosh Optimizer Based 2-Degree-of-Freedom Double Integral Feedback PID Controller for Power System Load Frequency Control
Algorithms · 08.03.2026 · 19 (3) · 202
DOI: 10.3390/a19030202 ↗Kurz gefasst
Fachartikel in der Zeitschrift Algorithms, online erschienen am 08.03.2026. Verfasst von Qingyi Zhang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
An improved Sinh Cosh optimizer (ISCHO) is proposed to resolve load frequency control (LFC) tasks. The original Sinh Cosh optimizer (SCHO) employs a fixed iteration-based switching function to balance exploration and exploitation, which lacks awareness of search dynamics and leads to inefficient optimization. Therefore, this paper proposes a “first grabbing then washing” strategy to dynamically balance exploration and development. The proposed ISCHO technique is tested on 13 benchmark functions and compared with Particle Swarm Optimization, Sine Cosine Algorithm, and Grey Wolf Optimizer, demonstrating superior optimization performance. Furthermore, a new controller based on the two-degree-of freedom PID controller (2DOF-PID), the two-degree-of freedom with double integral feedback PID controller (2DOF-PIDF-II), is proposed. A two-area multi-source interconnected power system, incorporating thermal, hydraulic, wind, and solar generation units with nonlinearities (GRC and GDB), uncertainties, and load fluctuations, is employed to validate the proposed approach. Quantitative results under step load perturbation demonstrate that the ISCHO-optimized 2DOF-PIDF-II controller significantly outperforms other methods. For area 1 frequency deviation, ISCHO reduces the maximum overshoot by 38.37%, 19.09%, and 21.48% compared to PSO, SCA, and SCHO. For tie-line power deviation, maximum overshoot is reduced by 53.00% compared to PSO. These results confirm that the proposed ISCHO-tuned 2DOF-PIDF-II controller substantially enhances system frequency stability under various operating conditions.
Zitieren
APA
Zhang, Q., Zou, K., & Zhang, Z. (2026). An Improved Sinh Cosh Optimizer Based 2-Degree-of-Freedom Double Integral Feedback PID Controller for Power System Load Frequency Control. Algorithms, 19(3), 202. https://doi.org/10.3390/a19030202
Vancouver
Zhang Q, Zou K, Zhang Z. An Improved Sinh Cosh Optimizer Based 2-Degree-of-Freedom Double Integral Feedback PID Controller for Power System Load Frequency Control. Algorithms. 2026;19(3):202. doi:10.3390/a19030202
BibTeX
@article{Zhang2026,
author = {Zhang, Qingyi and Zou, Kuansheng and Zhang, Zhaojun},
title = {An Improved Sinh Cosh Optimizer Based 2-Degree-of-Freedom Double Integral Feedback PID Controller for Power System Load Frequency Control},
journal = {Algorithms},
year = {2026},
volume = {19},
number = {3},
pages = {202},
doi = {10.3390/a19030202}
}
EUVIMED