Electrophysiological Markers of Ex-Situ Heart Performance in a Porcine Model of Cardiac Donation After Circulatory Death
Transplant International · 2024
DOI: 10.3389/ti.2024.13279 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transplant International, 2024. Verfasst von Jorik H Amesz und 9 weiteren Autor:innen. Beteiligte Einrichtung: Translational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands. Hauptthemen laut MEDLINE: Heart Transplantation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Normothermic ex-situ heart perfusion (ESHP) enables assessment of hearts donated after circulatory death (DCD) prior to transplantation. However, sensitive parameters of cardiac function of DCD hearts on ESHP are needed. This study proposes a novel approach using electrophysiological (EP) parameters derived from electrical mapping as biomarkers of post-ischemic cardiac performance. Porcine slaughterhouse hearts (PSH) were divided in two groups based on the type of warm ischemia (Group 1: 10 ± 1 min with animal depilation vs. Group 2: ≤5 min without depilation). Electrical mapping of the right (RV) and left ventricle (LV) was performed on ESHP. Potential voltages, slopes and conduction velocities were computed from unipolar electrograms and compared between groups. Voltages were lower in Group 1 compared to Group 2 (RV: 3.6 vs. 15.3 mV, p = 0.057; LV: 10.8 vs. 23.6 mV, p = 0.029). In addition, the percentage of low-voltage potentials was higher and potential slopes were flatter in Group 1. Voltages and slopes strongly correlated with the visual contractile performance of PSH, but showed weaker correlation with lactate profiles. In conclusion, unipolar potential voltages and potential slopes were decreased in hearts with severe warm ischemia. As such, EP parameters could aid transplantation teams in decision-making on transplantability of DCD hearts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Translational Cardiothoracic Surgery Research Lab, Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands.
- Translational Electrophysiology Lab, Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands.
- Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands.
- Erasmus MC Transplant Institute, Erasmus University Medical Center, Rotterdam, Netherlands.
- Department of Clinical Perfusion, Erasmus University Medical Center, Rotterdam, Netherlands.
- Department of Microelectronics, Faculty of Electrical Engineering, Mathematics and Computer Sciences, Circuits and Systems, Delft University of Technology, Delft, Netherlands.
Zitieren
APA
Amesz, J. H., Bierhuizen, M. F. A., Langmuur, S. J. J., Knops, P., van Steenis, Y. P., Dumay, D., van Schie, M. S., Manintveld, O. C., de Groot, N. M. S., & Taverne, Y. J. H. J. (2024). Electrophysiological Markers of Ex-Situ Heart Performance in a Porcine Model of Cardiac Donation After Circulatory Death. Transplant International. https://doi.org/10.3389/ti.2024.13279
Vancouver
Amesz JH, Bierhuizen MFA, Langmuur SJJ, Knops P, van Steenis YP, Dumay D, et al. Electrophysiological Markers of Ex-Situ Heart Performance in a Porcine Model of Cardiac Donation After Circulatory Death. Transplant International. 2024. doi:10.3389/ti.2024.13279
BibTeX
@article{Amesz2024,
author = {Amesz, Jorik H and Bierhuizen, Mark F A and Langmuur, Sanne J J and Knops, Paul and van Steenis, Yvar P and Dumay, Dwight and van Schie, Mathijs S and Manintveld, Olivier C and de Groot, Natasja M S and Taverne, Yannick J H J},
title = {Electrophysiological Markers of Ex-Situ Heart Performance in a Porcine Model of Cardiac Donation After Circulatory Death},
journal = {Transplant International},
year = {2024},
doi = {10.3389/ti.2024.13279}
}
EUVIMED