Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis
Pathology & Oncology Research · 23.11.2026 · 32
DOI: 10.3389/pore.2026.1612501 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pathology & Oncology Research, online erschienen am 23.11.2026. Verfasst von Dóra Kovács-Solymosi und 8 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background/objectives Minimizing radiation-induced late effects is critical in pediatric neuro-oncology, where long life expectancy is associated with treatment-related toxicity. We evaluated the 15-year institutional transition from three-dimensional conformal radiotherapy (3D-CRT) to volumetric modulated arc therapy (VMAT) and compared their dosimetric performance in pediatric focal brain radiotherapy (FBRT).
Methods
Between 2011 and 2025, 27,393 patients were treated, including 175 pediatric cases (≤18 years). FBRT cases were selected for dosimetric analysis because they are the most common pediatric brain irradiation at our institution and involve small-to-medium targets located near radiosensitive critical structures, enabling a sensitive comparison of technique-dependent dosimetric differences. FBRT plans from 27 patients were analyzed (3D-CRT: n = 13; VMAT: n = 14) using a unified script-based workflow in RayStation combined with a standardized AI-based auto-segmentation tool. Metrics included V95%, homogeneity index (HI), conformity index (CI), and high-dose spillage (V102%). Exploratory organ at risk (OAR) analysis was performed in a more restricted prescription uniform subgroup. In addition, overall survival (OS) was evaluated using available clinical follow-up data from FBRT patients.
Results
VMAT significantly reduced high-dose volumes (V102%: 0.01% vs. 0.78%, p = 3.8 × 10 −4 ), improved conformity (CI: 0.85 vs. 0.64, p = 0.008) and homogeneity (HI: 1.07 vs. 1.10, p = 0.048) compared with 3D-CRT. Target coverage was comparable. OAR analysis showed consistently reduced maximum doses to the optic chiasm and pituitary gland. No statistically significant difference in overall survival was observed between treatment techniques (p = 0.26).
Conclusion
Overall, our study demonstrates that the application of VMAT in pediatric focal brain irradiation improves the precision of dose distribution and may contribute to reducing long-term neurocognitive and endocrine toxicities. These findings support the clinical use of VMAT, with the potential to reduce late treatment-related toxicity in the pediatric patient population.
Zitieren
APA
Kovács-Solymosi, D., Mocsár, G., Simon, M., Gál, K., Papp, J., Macsi, L., Kiss, C., Kovács, Á., & Szegedi, I. (2026). Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis. Pathology & Oncology Research, 32. https://doi.org/10.3389/pore.2026.1612501
Vancouver
Kovács-Solymosi D, Mocsár G, Simon M, Gál K, Papp J, Macsi L, et al. Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis. Pathology & Oncology Research. 2026;32. doi:10.3389/pore.2026.1612501
BibTeX
@article{KovcsSolymosi2026,
author = {Kovács-Solymosi, Dóra and Mocsár, Gábor and Simon, Mihály and Gál, Kristóf and Papp, Judit and Macsi, Lilla and Kiss, Csongor and Kovács, Árpád and Szegedi, István},
title = {Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysis},
journal = {Pathology & Oncology Research},
year = {2026},
volume = {32},
doi = {10.3389/pore.2026.1612501}
}
EUVIMED