Evaluation of intestinal leakage pressure following unsutured intestinal biopsies performed with an automatic needle-core biopsy device
Frontiers in Veterinary Science · 20.07.2026 · 13
DOI: 10.3389/fvets.2026.1870783 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Veterinary Science, online erschienen am 20.07.2026. Verfasst von Esther Deglume und 5 weiteren Autor:innen. Beteiligte Einrichtung: IVC Evidencia, CHV des Cordeliers, Meaux, France. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To evaluate whether full-thickness intestinal biopsies performed with an automated needle-core device, without closure of the biopsy site, maintain adequate intestinal integrity in dogs and cats. Materials and methods This experimental study consisted of ex vivo testing on small intestinal segments from fresh canine and feline cadavers, and in vivo testing in dogs and cats undergoing enterectomy for unrelated indications. Full-thickness biopsies were performed using a 16-gauge automated needle-core device, with biopsy sites left unsutured. Intraluminal pressure was progressively increased using methylene blue–stained saline, and the initial leakage pressure (ILP) was recorded at first visible evidence of leakage. Cadaveric and in vivo ILP were compared to each other and to the reported maximal physiological intraluminal pressure of 25 mmHg.
Results
Thirty-nine cadaveric intestinal segments from seven animals were evaluated. The mean cadaveric ILP was 20.7 mmHg (95% CI [5.9–35.5 mmHg]), with leakage observed below 25 mmHg in 33 of them. In vivo ILP was measured in 12 patients (8 dogs, 4 cats), yielding 23 measurements. The mean in vivo ILP was 85.66 mmHg (95% CI [55.53, 115.78]), significantly exceeding the reference value of 25 mmHg, and all measurements remained above 26 mmHg.
Conclusion
Cadaveric leakage pressures were markedly lower than in vivo measurements, suggesting that cadaveric models may be poorly suited for evaluating intestinal pressure. In contrast, unsutured needle-core biopsy sites in live dogs and cats tolerated pressures above reported maximal physiological levels, immediately after biopsy. These findings suggest that the immediate risk of leakage at small (1.3-mm) unsutured biopsy sites is low; however, because healing and longer-term integrity were not evaluated, the necessity of routine closure cannot be established from these data. Further studies are needed to evaluate long-term safety and applicability in diseased intestines.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- IVC Evidencia, CHV des Cordeliers, Meaux, France.
- Clinique Vétérinaire AniCura VetRef, Beaucouzé, France.
- Department of Research, IVC Evidensia UK, Bristol, United Kingdom.
Zitieren
APA
Deglume, E., Aloisi, R., Delsol, G., Malkani, R., Libermann, S., & Etchepareborde, S. (2026). Evaluation of intestinal leakage pressure following unsutured intestinal biopsies performed with an automatic needle-core biopsy device. Frontiers in Veterinary Science, 13. https://doi.org/10.3389/fvets.2026.1870783
Vancouver
Deglume E, Aloisi R, Delsol G, Malkani R, Libermann S, Etchepareborde S. Evaluation of intestinal leakage pressure following unsutured intestinal biopsies performed with an automatic needle-core biopsy device. Frontiers in Veterinary Science. 2026;13. doi:10.3389/fvets.2026.1870783
BibTeX
@article{Deglume2026,
author = {Deglume, Esther and Aloisi, Roberta and Delsol, Guilhem and Malkani, Rachel and Libermann, Stéphane and Etchepareborde, Sébastien},
title = {Evaluation of intestinal leakage pressure following unsutured intestinal biopsies performed with an automatic needle-core biopsy device},
journal = {Frontiers in Veterinary Science},
year = {2026},
volume = {13},
doi = {10.3389/fvets.2026.1870783}
}
EUVIMED