EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of ultrasound probe location and sonographic findings used for the evaluation of pneumothorax in canine cadavers: a pilot study

Ashley Finch, Søren R Boysen, Valerie Madden, Phillipa J Johnson, Madison Hillstead, Cole Harding, Katrine Gillett, Julie Menard

Frontiers in Veterinary Science · 25.05.2026 · 13

DOI: 10.3389/fvets.2026.1707807 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Veterinary Science, online erschienen am 25.05.2026. Verfasst von Ashley Finch und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This pilot study aimed to compare sonographic findings at thoracic sites used to detect pneumothorax in canine cadavers.

Methods

Intubated frozen–thawed cadavers without pre-existing sonographic evidence of pneumothorax were included. Control, unilateral and bilateral pneumothorax groups were created, with the latter induced by infusion of air (3 mL/kg) under ultrasound guidance. Four blinded sonographers (two experts and two novices) evaluated positive-pressure-ventilated (PPV) cadavers placed in sternal recumbency. Lung sliding and B-lines were assessed at the chest tube site (CTS) and caudo-dorsal border (CDB), while the abnormal abdominal curtain sign (AACS) was evaluated along the abdominal curtain sign (ACS). When absence of lung sliding was noted, operators searched for a lung-point (LP). Presence or absence of pneumothorax was recorded for the CTS, CDB, AACS, combined CTS + LP, and CDB + AACS + LP (Modified PLUS). Post-study right and left horizontal beam radiography was used as the reference standard to quantify pneumothorax volume by a board-certified radiologist. Results were analyzed by Fisher’s exact test with a statistical significance set at p < 0.05.

Results

Mild pneumothorax was present in 10/16 hemithoraces, scant pneumothorax in 3/16, and no pneumothorax in 3/16. Combined accuracy, sensitivity, and specificity of all operators was 22% (9–40), 4% (0–20), 100% (54–100) for both CTS and CTS + LP; 53% (35–71), 42% (23–63), 100% (54–100) for CDB; 31% (16–50), 15% (4–35), 100% (54–100) for AACS; and 56% (38–74), 46% (27–67), 100%(54–100) for Modified PLUS, respectively. There was a significant difference in identification of pneumothorax between the CTS and CDB ( p = 0.00027), and CTS and Modified PLUS ( p = 0.0012) and between CTS + LP and Modified PLUS for all operator comparisons ( p = 0.00012).

Discussion

The site assessed (CDB vs. CTS) for lung sliding and the sonographic signs (AACS, lung sliding) evaluated with different POCUS protocols can influence the accuracy of diagnosing pneumothorax in PPV canine cadavers placed in sternal recumbency.

Schlagwörter

Stichwörter der Autor:innen

PLUSPOCUSchest tube sitecurtain signlung pointlung sliding

Autor:innen und Institutionen

  • Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada.
  • Paramount 24 Hour Animal Hospital, Calgary, AB, Canada.
  • VEG Emergency for Pet, White Plains, NY, United States.
  • College of Veterinary Medicine, Cornell University, Ithaca, NY, United States.
  • Faraday Veterinary Neuroimaging, Totnes, United Kingdom.

Zitieren

APA

Finch, A., Boysen, S. R., Madden, V., Johnson, P. J., Hillstead, M., Harding, C., Gillett, K., & Menard, J. (2026). Comparison of ultrasound probe location and sonographic findings used for the evaluation of pneumothorax in canine cadavers: a pilot study. Frontiers in Veterinary Science, 13. https://doi.org/10.3389/fvets.2026.1707807

Vancouver

Finch A, Boysen SR, Madden V, Johnson PJ, Hillstead M, Harding C, et al. Comparison of ultrasound probe location and sonographic findings used for the evaluation of pneumothorax in canine cadavers: a pilot study. Frontiers in Veterinary Science. 2026;13. doi:10.3389/fvets.2026.1707807

BibTeX
@article{Finch2026,
  author = {Finch, Ashley and Boysen, Søren R and Madden, Valerie and Johnson, Phillipa J and Hillstead, Madison and Harding, Cole and Gillett, Katrine and Menard, Julie},
  title = {Comparison of ultrasound probe location and sonographic findings used for the evaluation of pneumothorax in canine cadavers: a pilot study},
  journal = {Frontiers in Veterinary Science},
  year = {2026},
  volume = {13},
  doi = {10.3389/fvets.2026.1707807}
}
Kostenlos starten →