Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Surgery, online erschienen am 15.07.2026. Verfasst von Nan Yang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Supracondylar humerus fractures (SHFs) are among the most common fractures in pediatric patients. The following two surgical options are available for high-level extension-type pediatric supracondylar humeral fractures: Kirschner wire (K-wire) fixation and lateral external fixation. Evidence comparing the clinical outcomes of these two procedures remains insufficient. This study aimed to compare functional and radiological outcomes between the two surgical approaches.

Methods

This retrospective comparative study included 52 pediatric patients (15 treated with external fixation and 37 with K-wire fixation) with a minimum follow-up of 1 year. Outcome measures included open reduction rate, post-operative carrying angle, Baumann angle, humeral-capitellar angle, and complication rates (infection, ulnar nerve injury, and unacceptable cubitus varus). Elbow range of motion (ROM) was evaluated at serial follow-up points.

Results

No ulnar nerve injury, major loss of reduction, pin-tract infection, or elbow stiffness occurred in either group. The only significant between-group difference was a lower open reduction rate in the external fixation group ( P = 0.042). No statistically significant differences were observed in Baumann angle, humeral-capitellar angle, Flynn grade, carrying angle, or elbow ROM between the groups.

Conclusions

K-wire fixation and external fixation provide similarly satisfactory functional and radiological outcomes. External fixation offers no significant advantage over K-wire fixation for high-level extension-type supracondylar humeral fractures.

Schlagwörter

Stichwörter der Autor:innen

Baumann angleK-wire fixationexternal fixationrange of motionsupracondylar humerus fracture

Autor:innen und Institutionen

  • Department of Orthopedics, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Zitieren

APA

Yang, N., Zhang, Y., & Qin, H. (2026). External fixation is not superior to K-wire fixation in pediatric patients with high-level extension-type supracondylar humeral fractures. Frontiers in Surgery, 13. https://doi.org/10.3389/fsurg.2026.1853760

Vancouver

Yang N, Zhang Y, Qin H. External fixation is not superior to K-wire fixation in pediatric patients with high-level extension-type supracondylar humeral fractures. Frontiers in Surgery. 2026;13. doi:10.3389/fsurg.2026.1853760

BibTeX
@article{Yang2026,
  author = {Yang, Nan and Zhang, Yan and Qin, Hui},
  title = {External fixation is not superior to K-wire fixation in pediatric patients with high-level extension-type supracondylar humeral fractures},
  journal = {Frontiers in Surgery},
  year = {2026},
  volume = {13},
  doi = {10.3389/fsurg.2026.1853760}
}
Kostenlos starten →