The impact of gait pattern personalization on the perception of rigid robotic guidance: a pilot user experience evaluation
Frontiers in Robotics and AI · 30.10.2026 · 13
DOI: 10.3389/frobt.2026.1937649 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Robotics and AI, online erschienen am 30.10.2026. Verfasst von Beatrice Luciani und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cognitive Robotics Department, Delft University of Technology, Delft, Netherlands. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Robot-aided gait rehabilitation facilitates high-intensity and repeatable therapy. However, most exoskeletons rely on pre-recorded, non-personalized gait trajectories constrained to the sagittal plane, potentially limiting movement naturalness and user comfort.
Methods
We present a data-driven gait personalization framework for an exoskeleton that supports multi-planar motion, including hip abduction/adduction and pelvic translation and rotation. Personalized trajectories to individual participants were generated using regression models trained on anthropometric, demographic, and walking speed data from a normative database. In a within-subject experiment involving ten young unimpaired participants, these personalized trajectories were evaluated in regard to comfort, naturalness, and overall experience and compared against two standard patterns from the same database: one averaging all the trajectories, and one randomly selected.
Results
We did not find significant differences across pattern conditions, despite all trajectories being executed with high accuracy thanks to a stiff position-derivative controller. We found, however, that pattern conditions in later trials were rated as significantly more comfortable and natural than those in the first trial.
Discussion
Our results suggest that participants might have adapted to walking within the exoskeleton, regardless of the enforced gait pattern, and highlight the importance of integrating subjective feedback when designing personalized gait controllers and accounting for user adaptation during experimentation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cognitive Robotics Department, Delft University of Technology, Delft, Netherlands.
- Department of Rehabilitation Medicine, Erasmus Medical Centre, Rotterdam, Netherlands.
- Department of Biomechanical Engineering, Delft University of Technology, Delft, Netherlands.
- Institute of Automatic Control, RWTH Aachen University, Aachen, Germany.
- Department of Mechanical Engineering, FUM Center of Advanced Rehabilitation and Robotics Research (FUM CARE), Ferdowsi University of Mashhad, Mashhad, Iran.
- Walker Department of Mechanical Engineering, University of Texas at Austin, Austin, TX, United States.
Zitieren
APA
Luciani, B., Poggensee, K. L., Vallery, H., van den Berg, A., Woernle, S. D., Mogharabi, M., Gasperina, S. D., & Marchal-Crespo, L. (2026). The impact of gait pattern personalization on the perception of rigid robotic guidance: a pilot user experience evaluation. Frontiers in Robotics and AI, 13. https://doi.org/10.3389/frobt.2026.1937649
Vancouver
Luciani B, Poggensee KL, Vallery H, van den Berg A, Woernle SD, Mogharabi M, et al. The impact of gait pattern personalization on the perception of rigid robotic guidance: a pilot user experience evaluation. Frontiers in Robotics and AI. 2026;13. doi:10.3389/frobt.2026.1937649
BibTeX