EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pointing error evaluation in IRS-assisted VLC systems for indoor hospital environments: a comparative analytical study

Babak Sadeghi, Seyed Mohammad Sajad Sadough, Khadijeh Ali Mahmoodi

Frontiers in Communications and Networks · 26.08.2026 · 7

DOI: 10.3389/frcmn.2026.1908983 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Communications and Networks, online erschienen am 26.08.2026. Verfasst von Babak Sadeghi und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Visible light communication (VLC) has emerged as a promising technology for indoor wireless networks that offers immunity to electromagnetic interference and enhanced physical-layer security, properties that are particularly valuable in hospital and clinical environments. Intelligent reflecting surfaces (IRSs) have recently been proposed to extend VLC coverage by enabling non-line-of-sight (NLoS) transmission when direct optical paths are blocked by medical staff, equipment, or movable infrastructure. However, the cascaded transmitter–IRS–receiver geometry introduces compounded misalignment effects that are not present in conventional line-of-sight (LoS) links, and their analytical characterization remains an open problem. This study presents a unified analytical framework for quantifying and comparing pointing errors on conventional LoS and IRS-assisted VLC links in indoor hospital environments. Closed-form expressions are derived for the composite pointing-error variance, and the radial displacement is modeled using a Rayleigh distribution. Analytical expressions for the average received power, electrical signal-to-noise ratio (SNR), and outage probability are then obtained for both link configurations. The results indicate that IRS deployment results in an SNR degradation of approximately 3–5 dB under practical conditions, and the probability of outage increases significantly with the variance of the pointing error, underscoring the importance of precise beam alignment and robust IRS control for reliable hospital wireless connectivity.

Zitieren

APA

Sadeghi, B., Sadough, S. M. S., & Mahmoodi, K. A. (2026). Pointing error evaluation in IRS-assisted VLC systems for indoor hospital environments: a comparative analytical study. Frontiers in Communications and Networks, 7. https://doi.org/10.3389/frcmn.2026.1908983

Vancouver

Sadeghi B, Sadough SMS, Mahmoodi KA. Pointing error evaluation in IRS-assisted VLC systems for indoor hospital environments: a comparative analytical study. Frontiers in Communications and Networks. 2026;7. doi:10.3389/frcmn.2026.1908983

BibTeX
@article{Sadeghi2026,
  author = {Sadeghi, Babak and Sadough, Seyed Mohammad Sajad and Mahmoodi, Khadijeh Ali},
  title = {Pointing error evaluation in IRS-assisted VLC systems for indoor hospital environments: a comparative analytical study},
  journal = {Frontiers in Communications and Networks},
  year = {2026},
  volume = {7},
  doi = {10.3389/frcmn.2026.1908983}
}
Kostenlos starten →