AI-driven ANN–PSO smart-inverter capacity allocation at preselected buses under meteorological uncertainty

Selman Djeffal, Badreddine Bendriss, Abdelhamid Ghoul, Mohamed Razi Morakchi

Frontiers in Artificial Intelligence · 20.08.2026 · 9

DOI: 10.3389/frai.2026.1896551 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Artificial Intelligence, online erschienen am 20.08.2026. Verfasst von Selman Djeffal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, National Polytechnic School of Constantine, Constantine, Algeria. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Radial distribution grids require renewable planning methods that jointly account for meteorological generation, WT/PV capacity allocation, and smart-inverter voltage support.

Methods

An ANN-PSO-VoltVAR framework was developed using 2012-2021 NASA POWER irradiance, wind-speed, and temperature data for In Salah, Algeria. Renewable uncertainty was represented by 12 stratified Weibull-Beta scenarios and an expected-cost/CVaR objective. The mixed decision vector optimized WT units, PV strings, and voltage-dependent inverter support at four preselected IEEE 85-bus locations. An exact backward/forward-sweep module on the standard 33-bus feeder independently verified the load-flow implementation.

Results

The tuned ANN achieved an RMSE of 1.6323 kW, an MAE of 1.2314 kW, and an R-squared value of 0.99999. The verified five-start mean-profile solution reduced mean active loss to 15.9900 kW and voltage deviation to 0.051082 p.u., while increasing minimum voltage to 0.98213 p.u. and minimum VSI to 0.96307. Relative to IFLO, the respective improvements were 54.57%, 22.49%, 1.21%, and 8.41%.

Discussion

The ablation analysis showed that capacity sizing accounted for most of the loss reduction, whereas Volt-VAR support produced the clearer additional voltage-security gains. Because the IEEE 85-bus electrical response is benchmark-calibrated rather than fully reconstructed, the findings should be interpreted as a reproducible proof-of-concept. Direct full-feeder validation on the IEEE 85-bus system and other networks remains necessary.

Schlagwörter

Stichwörter der Autor:innen

Volt–VAR controlartificial neural networkparticle swarm optimizationradial distribution gridrenewable capacity allocationscenario-based uncertaintysmart invertervoltage stability index

Autor:innen und Institutionen

  • Department of Mechanical Engineering, National Polytechnic School of Constantine, Constantine, Algeria.
  • QUERE Laboratory, Department of Electrical Engineering, Ferhat Abbas University, Setif, Algeria.
  • Automatic Control, Department of Computer Science, Electrical and Space Engineering, Luleå University of Technology, Luleå, Sweden.
  • Department of Electromechanics, Faculty of Construction Engineering, University of Tizi ouzzou UMMTO, Tizi Ouzou, Algeria.

Zitieren

APA

Djeffal, S., Bendriss, B., Ghoul, A., & Morakchi, M. R. (2026). AI-driven ANN–PSO smart-inverter capacity allocation at preselected buses under meteorological uncertainty. Frontiers in Artificial Intelligence, 9. https://doi.org/10.3389/frai.2026.1896551

Vancouver

Djeffal S, Bendriss B, Ghoul A, Morakchi MR. AI-driven ANN–PSO smart-inverter capacity allocation at preselected buses under meteorological uncertainty. Frontiers in Artificial Intelligence. 2026;9. doi:10.3389/frai.2026.1896551

BibTeX
@article{Djeffal2026,
  author = {Djeffal, Selman and Bendriss, Badreddine and Ghoul, Abdelhamid and Morakchi, Mohamed Razi},
  title = {AI-driven ANN–PSO smart-inverter capacity allocation at preselected buses under meteorological uncertainty},
  journal = {Frontiers in Artificial Intelligence},
  year = {2026},
  volume = {9},
  doi = {10.3389/frai.2026.1896551}
}
Kostenlos starten →