A systematic benchmarking of deep transfer learning architectures and optimization strategies for COVID-19 detection from lung ultrasound images
Frontiers in Radiology · 06.11.2026 · 6
DOI: 10.3389/fradi.2026.1848424 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Radiology, online erschienen am 06.11.2026. Verfasst von Chandrika Dadhirao und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science and Engineering, GITAM Deemed to be University, Visakhapatnam, India. Die Arbeit nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The COVID-19 pandemic imposed severe burdens on global health infrastructure, underscoring the urgent need for rapid, reliable, and scalable diagnostic technologies. Conventional radiological modalities such as chest X-rays and computed tomography (CT) face critical deployment barriers, including ionizing radiation exposure, elevated procedural costs, and substantial infection-control risks in resource-constrained settings. Lung ultrasound (LUS) presents a compelling alternative owing to its portability, absence of ionizing radiation, and suitability for point-of-care application; however, systematic analysis of deep learning architectures optimized for LUS-based COVID-19 classification remains limited.
Methods
To address this gap, this study presents a comprehensive benchmarking framework in which 13 pretrained convolutional neural network (CNN) architectures—AlexNet, VGG-16, VGG-19, ResNet-50, ResNet-101, ResNet-152, DenseNet-121, DenseNet-169, DenseNet-201, InceptionV3, Inception-ResNetV2, MobileNetV2, and Xception—were evaluated under seven gradient-based optimization strategies: SGD, Adagrad, RMSProp, Adadelta, Adam, AdaMax, and Nadam. Transfer learning was applied uniformly across all architectures to compensate for the limited scale of the publicly available POCOVID-Net dataset, which comprised 455 LUS frames from confirmed COVID-19 cases and 226 frames from non-COVID subjects. In addition, geometric transformation-based data augmentation was employed to mitigate the effects of class imbalance and improve inter-patient generalization.
Results
Among the architecture–optimizer combinations evaluated under the hold-out scenario, DenseNet-121 with the Adam optimizer achieved perfect classification with 100% accuracy, surpassing all previously reported LUS-based COVID-19 detection methods evaluated under comparable single-dataset conditions. Given the risk that a single hold-out split may overstate performance, rigorous stratified 5-fold cross-validation was subsequently performed on this best-performing hold-out model to ensure robustness and address concerns regarding overfitting. This yielded a mean accuracy of 99.11% ± 0.35%, sensitivity of 99.41% ± 0.31%, specificity of 99.18% ± 0.38%, F1-score of 99.36% ± 0.29%, and AUC of 99.45% ± 0.25%. Discussion/Conclusion Despite consistently strong performance across both evaluation schemes, these results were derived from a single, limited-diversity public dataset and, therefore, represent a methodological benchmark rather than a validated estimate of real-world performance. External multicenter validation is necessary before clinical application of the model. Nonetheless, the evaluated DenseNet-121 framework holds practical utility as a rapid triage aid and complementary screening tool within clinical workflows, particularly in low-resource environments where CT infrastructure is unavailable.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Computer Science and Engineering, GITAM Deemed to be University, Visakhapatnam, India.
- Department of Electronics and Communication Engineering, Vasavi College of Engineering, Hyderabad, India.
- Department of Information Technology, Anil Neerukonda Institute of Technology and Sciences, Sanghivalasa, India.
- Department of Electronics and Communication Engineering, Amrita Vishwa Vidyapeetham, Amaravati Campus, Guntur, Andhra Pradesh, India.
- Department of Electronics and Communication Engineering, NERIST - North Eastern Regional Institute of Science and Technology, Nirjuli, Arunachal Pradesh, India.
- Amrita School of Computing, Amrita Vishwa Vidyapeetham, Amaravati Campus, Guntur, Andhra Pradesh, India.
Zitieren
APA
Dadhirao, C., Kamireddy, R. R., Sadi, R. P. R., Kadha, V., Mishra, M., & Batchu, R. K. (2026). A systematic benchmarking of deep transfer learning architectures and optimization strategies for COVID-19 detection from lung ultrasound images. Frontiers in Radiology, 6. https://doi.org/10.3389/fradi.2026.1848424
Vancouver
Dadhirao C, Kamireddy RR, Sadi RPR, Kadha V, Mishra M, Batchu RK. A systematic benchmarking of deep transfer learning architectures and optimization strategies for COVID-19 detection from lung ultrasound images. Frontiers in Radiology. 2026;6. doi:10.3389/fradi.2026.1848424
BibTeX
@article{Dadhirao2026,
author = {Dadhirao, Chandrika and Kamireddy, Rasool Reddy and Sadi, Ram Prasad Reddy and Kadha, Vijayakumar and Mishra, Madhusudhan and Batchu, Raj Kumar},
title = {A systematic benchmarking of deep transfer learning architectures and optimization strategies for COVID-19 detection from lung ultrasound images},
journal = {Frontiers in Radiology},
year = {2026},
volume = {6},
doi = {10.3389/fradi.2026.1848424}
}
EUVIMED